ICGOO在线商城 > 射频/IF 和 RFID > RF 定向耦合器 > X3C09P2-30S
数量阶梯 | 香港交货 | 国内含税 |
+xxxx | $xxxx | ¥xxxx |
查看当月历史价格
查看今年历史价格
X3C09P2-30S产品简介:
ICGOO电子元器件商城为您提供X3C09P2-30S由Anaren Microwave设计生产,在icgoo商城现货销售,并且可以通过原厂、代理商等渠道进行代购。 X3C09P2-30S价格参考¥24.11-¥48.25。Anaren MicrowaveX3C09P2-30S封装/规格:RF 定向耦合器, RF Directional Coupler AMPS, CDMA, WCDMA 800MHz ~ 1GHz 30.2dB 225W 2520 (6450 Metric)。您可以下载X3C09P2-30S参考资料、Datasheet数据手册功能说明书,资料中有X3C09P2-30S 详细功能的应用电路图电压和使用方法及教程。
参数 | 数值 |
产品目录 | |
描述 | COUPLER 90DEG 800-1000MHZ 30DB信号调节 800-1000MHz IL:.10dB VSWR:1.22 -55 to 95C |
产品分类 | |
品牌 | Anaren |
产品手册 | |
产品图片 | |
rohs | 符合RoHS无铅 / 符合限制有害物质指令(RoHS)规范要求 |
产品系列 | Anaren X3C09P2-30SXinger III® |
mouser_ship_limit | 该产品可能需要其他文件才能进口到中国。 |
数据手册 | |
产品型号 | X3C09P2-30S |
RoHS指令信息 | |
产品 | Directional Couplers |
产品种类 | 信号调节 |
介入损耗 | 0.1 dB |
供应商器件封装 | 4-SMD |
其它名称 | 1173-1107-6 |
功率-最大值 | 225W |
包装 | Digi-Reel® |
商标 | Anaren |
回波损耗 | 24.9dB |
封装 | Reel |
封装/外壳 | 2520(6450 公制) |
封装/箱体 | 6.35 mm x 5.08 mm |
工作温度范围 | - 55 C to + 95 C |
工厂包装数量 | 2000 |
应用 | AMPS,CDMA,WCDMA |
插入损耗 | 0.1dB |
标准包装 | 1 |
端接类型 | SMD/SMT |
耦合器类型 | 标准 |
耦合系数 | 30.2dB |
隔离 | - |
频率 | 800MHz ~ 1GHz |
频率范围 | 800 MHz to 1000 MHz |
Model X3C09P2-30S Rev C 30 dB Directional Coupler Description The X3C09P2-30S is a low profile, high performance 30dB directional coupler in a new easy to use, manufacturing friendly surface mount package. It is designed for AMPS, GSM, WCDMA and LTE band applications. The X3C09P2-30S is designed particularly for power and frequency detection, as well as for VSWR monitoring, where tightly controlled coupling and low insertion loss is required. It can be used in high power applications up to 225 Watts. Parts have been subjected to rigorous qualification testing and they are manufactured using materials with coefficients of thermal expansion (CTE) compatible with common substrates such as FR4, G- 10, RF-35, RO4003 and polyimide. Produced with 6 of 6 RoHS compliant tin immersion finish Electrical Specifications ** Features: Mean Insertion Frequency VSWR Directivity 800 - 1000 MHz Coupling Loss AMPS, GSM, WCDMA and MHz dB dB Max Max : 1 dB Min LTE band 800 - 1000 30.2 ± 1.50 0.10 1.15 20 High Power 869 - 894 30.0 ± 1.50 0.075 1.12 20 Very Low Loss 925 - 960 30.0 ± 1.50 0.075 1.12 20 Tight Coupling 700 – 800 30.4 ± 1.50 0.10 1.22 20 High Directivity Production Friendly Frequency Operating Power JC Tape and Reel Sensitivity Temp. Lead Free dB Max Avg. CW ºC/Watt ºC Watts ± 0.40 225 45 -55 to +95 ± 0.1 225 45 -55 to +95 ± 0.1 225 45 -55 to +95 ± 0.40 225 45 -55 to +95 **Specification based on performance of unit properly installed on Anaren Test Board 61015-0001. Refer to Specifications subject to change without notice. Refer to parameter definitions for details. Mechanical Outline Dimensions are in Inches [Millimeters] X3C19P2-30S Mechanical Outline Tolerances are Non-Cumulative Available on Tape USA/Canada: (315) 432-8909 and Reel for Pick and Toll Free: (800) 411-6596 Place Manufacturing. Europe: +44 2392-232392
Model X3C09P2-30S Rev C Directional Coupler Pin Configuration The X3C09P2-30S has an orientation marker to denote Pin 1. Once port one has been identified the other ports are known automatically. Please see the chart below for clarification: 30dB Coupler Pin Configuration Pin 1 Pin 2 Pin 3 Pin 4 Input Direct Isolated Coupled Direct Input Coupled Isolated Note: The direct port has a DC connection to the input port and the coupled port has a DC connection to the isolated port. For optimum IL and power handling performance, use Pin 1 or Pin 2 as inputs. USA/Canada: (315) 432-8909 Available on Tape and Toll Free: (800) 411-6596 Reel for Pick and Place Europe: +44 2392-232392 Manufacturing.
Model X3C09P2-30S Rev C Insertion Loss and Power Derating Curves Typical Insertion Loss Derating Curve for X3C09P2-30 X3C09P2-30 Power Derating Curve 0 450 -0.01 typical insertion loss (f=800Mhz) 400 typical insertion loss (f=894Mhz) 700 - 1000MHz -0.02 typical insertion loss (f=960Mhz) 350 typical insertion loss (f=1000Mhz) -0.03 B) s) 300 n Loss (d -0.04 er (Watt 222550 sertio -0.05 Pow 200 n I -0.06 150 -0.07 100 -0.08 50 -0.09 0 95 -100 -50 0 50 100 150 200 0 20 40 60 80 100 120 140 160 180 Temperature of the Part (oC) Mounting Interface Temperature (oC) Insertion Loss Derating: Power Derating: The insertion loss, at a given frequency, of a group of The power handling and corresponding power derating couplers is measured at 25C and then averaged. The plots are a function of the thermal resistance, mounting measurements are performed under small signal surface temperature (base plate temperature), maximum conditions (i.e. using a Vector Network Analyzer). The continuous operating temperature of the coupler, and the process is repeated at 85C and 150C. A best-fit line for thermal insertion loss. The thermal insertion loss is the measured data is computed and then plotted from - defined in the Power Handling section of the data sheet. 55C to 150C. As the mounting interface temperature approaches the maximum continuous operating temperature, the power handling decreases to zero. If mounting temperature is greater than 95C, Xinger coupler will perform reliably as long as the input power is derated to the curve above. Available on Tape USA/Canada: (315) 432-8909 and Reel for Pick and Toll Free: (800) 411-6596 Place Manufacturing. Europe: +44 2392-232392
Model X3C09P2-30S Rev C Typical Performance (-55°C, 25°C, 95°C & 125°C): 700-1000 MHz Return Loss for X3C09P2-30S(Feeding port1) Return Loss for X3C09P2-30S(Feeding port2) 0 0 -55C -55C 25C 25C -10 95C -10 95C 125C 125C -20 -20 B) B) d -30 d -30 s ( s ( s s o o L L n n ur -40 ur -40 et et R R -50 -50 -60 -60 -70 -70 700 750 800 850 900 950 1000 700 750 800 850 900 950 1000 Freq (MHz) Freq (MHz) Return Loss for X3C09P2-30S(Feeding port3) Return Loss for X3C09P2-30S(Feeding port4) 0 0 -55C -55C 25C 25C -10 95C -10 95C 125C 125C -20 -20 B) B) d -30 d -30 s ( s ( s s o o L L n n Retur -40 Retur -40 -50 -50 -60 -60 -70 -70 700 750 800 850 900 950 1000 700 750 800 850 900 950 1000 Freq (MHz) Freq(MHz) USA/Canada: (315) 432-8909 Available on Tape and Toll Free: (800) 411-6596 Reel for Pick and Place Europe: +44 2392-232392 Manufacturing.
Model X3C09P2-30S Rev C Typical Performance (-55°C, 25°C, 95°C & 125°C): 700-1000 MHz Coupling for X3C09P2-30S(Feeding port1) Directivity for X3C09P2-30S(Feeding port1) -28 0 -55C -55C 25C 25C -28.5 95C 95C 125C -10 125C -29 -20 -29.5 Coupling [dB] -30 Directivity (dB) -30 -30.5 -40 -31 -50 -31.5 -32 -60 700 750 800 850 900 950 1000 700 750 800 850 900 950 1000 Freq (MHz) Freq (MHz) Insertion Loss for X3C09P2-30S(Feeding port1) 0 Transmission Loss for X3C09P2-30S(Feeding port1) -55C 0 -55C 25C 25C -0.02 95C -0.02 95C 125C 125C -0.04 -0.04 -0.06 -0.06 B) s (dB) -0.08 oss (d -0.08 s L Insertion Lo -0-0.1.21 Transmission -0-0.1.12 -0.14 -0.14 -0.16 -0.16 -0.18 -0.18 -0.2 -0.2 700 750 800 850 900 950 1000 700 750 800 850 900 950 1000 Freq (MHz) Freq (MHz) Available on Tape USA/Canada: (315) 432-8909 and Reel for Pick and Toll Free: (800) 411-6596 Place Manufacturing. Europe: +44 2392-232392
Model X3C09P2-30S Rev C Definition of Measured Specifications Parameter Definition Mathematical Representation V max The impedance match of VSWR = V VSWR the coupler to a 50 min (Voltage Standing Wave Ratio) system. A VSWR of 1:1 is Vmax = voltage maxima of a standing wave optimal. Vmin = voltage minima of a standing wave The impedance match of the coupler to a 50 VSWR 1 Return Loss system. Return Loss is Return Loss (dB)= 20log VSWR-1 an alternate means to express VSWR. At a given frequency (n), P () coupling is the input Coupling (dB) = C()10log in n n P () power divided by the cpl n power at the coupled Mean Coupling port. Mean coupling is N the average value of the C() n coupling values in the Mean Coupling (dB) = n1 band. N is the number of N frequencies in the band. The input power divided P in Insertion Loss by the sum of the power 10log P P at the two output ports. cpl direct The input power divided P in Transmission Loss by the power at the direct 10log P port. direct The power at the P coupled port divided by cpl Directivity 10log the power at the isolated P iso port. The decibel difference between the maximum in band coupling value and Max Coupling (dB) – Mean Coupling (dB) the mean coupling, and Frequency Sensitivity and the decibel difference Min Coupling (dB) – Mean Coupling (dB) between the minimum in band coupling value and the mean coupling. USA/Canada: (315) 432-8909 Available on Tape and Toll Free: (800) 411-6596 Reel for Pick and Place Europe: +44 2392-232392 Manufacturing.
Model X3C09P2-30S Rev C Notes on RF Testing and Circuit Layout The X3C09P2-30S Surface Mount Couplers require the use of a test fixture for verification of RF performance. This test fixture is designed to evaluate the coupler in the same environment that is recommended for installation. Enclosed inside the test fixture, is a circuit board that is fabricated using the recommended footprint. The part being tested is placed into the test fixture and pressure is applied to the top of the device using a pneumatic piston. A four port Vector Network Analyzer is connected to the fixture and is used to measure the S-parameters of the part. Worst case values for each parameter are found and compared to the specification. These worst case values are reported to the test equipment operator along with a Pass or Fail flag. See the illustrations below. Test Board 30 dB In Fixture Test Board Test Station Available on Tape USA/Canada: (315) 432-8909 and Reel for Pick and Toll Free: (800) 411-6596 Place Manufacturing. Europe: +44 2392-232392
Model X3C09P2-30S Rev C The effects of the test fixture on the measured data must be minimized in order to accurately determine the performance of the device under test. If the line impedance is anything other than 50 and/or there is a discontinuity at the microstrip to SMA interface, there will be errors in the data for the device under test. The test environment can never be “perfect”, but the procedure used to build and evaluate the test boards (outlined below) demonstrates an attempt to minimize the errors associated with testing these devices. The lower the signal level that is being measured, the more impact the fixture errors will have on the data. Parameters such as Return Loss and Isolation/Directivity, which are specified as low as 27dB and typically measure at much lower levels, will present the greatest measurement challenge. The test fixture errors introduce an uncertainty to the measured data. Fixture errors can make the performance of the device under test look better or worse than it actually is. For example, if a device has a known return loss of 30dB and a discontinuity with a magnitude of –35dB is introduced into the measurement path, the new measured Return Loss data could read anywhere between –26dB and –37dB. This same discontinuity could introduce an insertion phase error of up to 1. There are different techniques used throughout the industry to minimize the affects of the test fixture on the measurement data. Anaren uses the following design and de-embedding criteria: Test boards have been designed and parameters specified to provide trace impedances of 50 1. Furthermore, discontinuities at the SMA to microstrip interface are required to be less than –35dB and insertion phase errors (due to differences in the connector interface discontinuities and the electrical line length) should be less than 0.25 from the median value of the four paths. A “Thru” circuit board is built. This is a two port, microstrip board that uses the same SMA to microstrip interface and has the same total length (insertion phase) as the actual test board. The “Thru” board must meet the same stringent requirements as the test board. The insertion loss and insertion phase of the “Thru” board are measured and stored. This data is used to completely de-embed the device under test from the test fixture. The de-embedded data is available in S-parameter form on the Anaren website (www.anaren.com). Note: The S-parameter files that are available on the anaren.com website include data for frequencies that are outside of the specified band. It is important to note that the test fixture is designed for optimum performance through 2.3GHz. Some degradation in the test fixture performance will occur above this frequency and connector interface discontinuities of –25dB or more can be expected. This larger discontinuity will affect the data at frequencies above 2.3GHz. Circuit Board Layout The dimensions for the Anaren test board are shown below. The test board is printed on Rogers RO4350 material that is 0.030” thick. Consider the case when a different material is used. First, the pad size must remain the same to accommodate the part. But, if the material thickness or dielectric constant (or both) changes, the reactance at the interface to the coupler will also change. Second, the linewidth required for 50 will be different and this will introduce a step in the line at the pad where the coupler interfaces with the printed microstrip trace. Both of these conditions will affect the performance of the part. To achieve the specified performance, serious attention must be given to the design and layout of the circuit environment in which this component will be used. If a different circuit board material is used, an attempt should be made to achieve the same interface pad reactance that is present on the Anaren RO4350 test board. When thinner circuit board material is used, the ground plane will be closer to the pad yielding more capacitance for the same size interface pad. The same is true if the dielectric constant of the circuit board material is higher than is used on the Anaren test board. In both of these cases, narrowing the line before the interface pad will introduce a series inductance, which, when properly tuned, will compensate for the extra capacitive reactance. If a thicker circuit board or one with a lower dielectric constant is used, USA/Canada: (315) 432-8909 Available on Tape and Toll Free: (800) 411-6596 Reel for Pick and Place Europe: +44 2392-232392 Manufacturing.
Model X3C09P2-30S Rev C the interface pad will have less capacitive reactance than the Anaren test board. In this case, a wider section of line before the interface pad (or a larger interface pad) will introduce a shunt capacitance and when properly tuned will match the performance of the Anaren test board. Notice that the board layout for the 3dB and 5dB couplers is different from that of the 10dB and 20dB couplers. The test board for the 3dB and 5dB couplers has all four traces interfacing with the coupler at the same angle. The test board for the 10dB, 20dB and 30dB couplers has two traces approaching at one angle and the other two traces at a different angle. The entry angle of the traces has a significant impact on the RF performance and these parts have been optimized for the layout used on the test boards shown below. 30dB Test Board Testing Sample Parts Supplied on Anaren Test Boards If you have received a coupler installed on an Anaren produced microstrip test board, please remember to remove the loss of the test board from the measured data. The loss is small enough that it is not of concern for Return Loss and Isolation/Directivity, but it should certainly be considered when measuring coupling and calculating the insertion loss of the coupler. An S-parameter file for a “Thru” board (see description of “Thru” board above) will be supplied upon request. As a first order approximation, one should consider the following loss estimates: Frequency Band Avg. Ins. Loss of Test Board @ 25C 410 – 500 MHz ~ 0.04dB 800 - 1000 MHz ~ 0.06dB 1700 – 2300 MHz ~0.14dB 2300 – 2700 MHz ~0.155dB 3300 – 3800 MHz ~0.20dB For example, a 1900MHz, 10dB coupler on a test board may measure –10.30dB from input to the coupled port at some frequency, F1. When the loss of the test board is removed, the coupling at F1 becomes -10.18dB (-10.30dB + 0.12dB). This compensation must be made to both the coupled and direct path measurements when calculating insertion loss. The loss estimates in the table above come from room temperature measurements. It is important to note that the loss of the test board will change with temperature. This fact must be considered if the coupler is to be evaluated at other temperatures. Available on Tape USA/Canada: (315) 432-8909 and Reel for Pick and Toll Free: (800) 411-6596 Place Manufacturing. Europe: +44 2392-232392
Model X3C09P2-30S Rev C Peak Power Handling High-Pot testing of these couplers during the qualification procedure resulted in a minimum breakdown voltage of 1.40 kV. This voltage level corresponds to a breakdown resistance capable of handling at least 12dB peaks over average power levels, for very short durations. The breakdown location consistently occurred across the air interface at the coupler contact pads (see illustration below). The breakdown levels at these points will be affected by any contamination in the gap area around these pads. These areas must be kept clean for optimum performance. It is recommended that the user test for voltage breakdown under the maximum operating conditions and over worst case modulation induced power peaking. This evaluation should also include extreme environmental conditions (such as high humidity). Orientation Marker A printed circular feature appears on the top surface of the coupler to designate Pin 1. This orientation marker is not intended to limit the use of the symmetry that these couplers exhibit but rather to facilitate consistent placement of these parts into the tape and reel package. This ensures that the components are always delivered with the same orientation. Refer to the table on page 2 of the data sheet for allowable pin configurations. Test Plan Xinger III 30dB couplers are manufactured in large panels and then separated. A sample population of parts is RF small signal tested at room temperature in the fixture described above. All parts are DC tested for shorts/opens. (See “Qualification Flow Chart” section for details on the accelerated life test procedures.) USA/Canada: (315) 432-8909 Available on Tape and Toll Free: (800) 411-6596 Reel for Pick and Place Europe: +44 2392-232392 Manufacturing.
Model X3C09P2-30S Rev C Power Handling The average power handling (total input power) of a Xinger coupler is a function of: Internal circuit temperature. Unit mounting interface temperature. Unit thermal resistance Power dissipated within the unit. All thermal calculations are based on the following assumptions: The unit has reached a steady state operating condition. Maximum mounting interface temperature is 95oC. Conduction Heat Transfer through the mounting interface. No Convection Heat Transfer. No Radiation Heat Transfer. The material properties are constant over the operating temperature range. Finite element simulations are made for each unit. The simulation results are used to calculate the unit thermal resistance. The finite element simulation requires the following inputs: Unit material stack-up. Material properties. Circuit geometry. Mounting interface temperature. Thermal load (dissipated power). The classical definition for dissipated power is temperature delta (T) divided by thermal resistance (R). The dissipated power (P ) can also be calculated as a function of the total input power (P ) and the thermal insertion loss dis in (IL ): therm T ILtherm P P 110 10 (W) dis in (1) R Power flow and nomenclature for an “H” style coupler is shown in Figure 1. Available on Tape USA/Canada: (315) 432-8909 and Reel for Pick and Toll Free: (800) 411-6596 Place Manufacturing. Europe: +44 2392-232392
Model X3C09P2-30S Rev C P P (RL) P (DC) In Out Out Input Port Pin 1 Direct Port Coupled Port Pin 4 Isolated Port P (CPL) P (ISO) Out Out Figure 1 The coupler is excited at the input port with P (watts) of power. Assuming the coupler is not ideal, and that there are in no radiation losses, power will exit the coupler at all four ports. Symbolically written, P is the power that is out(RL) returned to the source because of impedance mismatch, P is the power at the isolated port, P is the out(ISO) out(CPL) power at the coupled port, and P is the power at the direct port. out(DC) At Anaren, insertion loss is defined as the log of the input power divided by the sum of the power at the coupled and direct ports: Note: in this document, insertion loss is taken to be a positive number. In many places, insertion loss is written as a negative number. Obviously, a mere sign change equates the two quantities. P IL 10log in (dB) 10 (2) P P out(CPL) out(DC) In terms of S-parameters, IL can be computed as follows: 2 2 IL 10log S S (dB) 10 31 41 (3) We notice that this insertion loss value includes the power lost because of return loss as well as power lost to the isolated port. For thermal calculations, we are only interested in the power lost “inside” the coupler. Since P is lost in the out(RL) source termination and P is lost in an external termination, they are not be included in the insertion loss for out(ISO) thermal calculations. Therefore, we define a new insertion loss value solely to be used for thermal calculations: USA/Canada: (315) 432-8909 Available on Tape and Toll Free: (800) 411-6596 Reel for Pick and Place Europe: +44 2392-232392 Manufacturing.
Model X3C09P2-30S Rev C P IL 10log in (dB) therm 10 (4) P P P P out(CPL) out(DC) out(ISO) out(RL) In terms of S-parameters, IL can be computed as follows: therm 2 2 2 2 IL 10log S S S S (dB) therm 10 11 21 31 41 (5) The thermal resistance and power dissipated within the unit are then used to calculate the average total input power of the unit. The average total steady state input power (P ) therefore is: in T P R P dis (W) in ILtherm ILtherm (6) 110 10 110 10 Where the temperature delta is the circuit temperature (T ) minus the mounting interface temperature (T ): circ mnt T T T (oC) (7) circ mnt The maximum allowable circuit temperature is defined by the properties of the materials used to construct the unit. Multiple material combinations and bonding techniques are used within the Xinger III product family to optimize RF performance. Consequently the maximum allowable circuit temperature varies. Please note that the circuit temperature is not a function of the Xinger case (top surface) temperature. Therefore, the case temperature cannot be used as a boundary condition for power handling calculations. Due to the numerous board materials and mounting configurations used in specific customer configurations, it is the end users responsibility to ensure that the Xinger III coupler mounting interface temperature is maintained within the limits defined on the power derating plots for the required average power handling. Additionally appropriate solder composition is required to prevent reflow or fatigue failure at the RF ports. Finally, reliability is improved when the mounting interface and RF port temperatures are kept to a minimum. The power-derating curve illustrates how changes in the mounting interface temperature result in converse changes of the power handling of the coupler. Available on Tape USA/Canada: (315) 432-8909 and Reel for Pick and Toll Free: (800) 411-6596 Place Manufacturing. Europe: +44 2392-232392
Model X3C09P2-30S Rev C Mounting Coupler Mounting Process In order for Xinger surface mount couplers to work optimally, there must be 50Ω transmission lines leading The process for assembling this component is a to and from all of the RF ports. Also, there must be a conventional surface mount process as shown in Figure very good ground plane underneath the part to ensure 1. This process is conducive to both low and high volume proper electrical performance. If either of these two usage. conditions is not satisfied, insertion loss, coupling, VSWR and isolation may not meet published specifications. Overall ground is improved if a dense population of plated through holes connect the top and bottom ground layers of the PCB. This minimizes ground inductance Figure 1: Surface Mounting Process Steps and improves ground continuity. All of the Xinger hybrid and directional couplers are constructed from ceramic Storage of Components: The Xinger III products are filled PTFE composites which possess excellent electrical available in either an immersion tin or tin-lead finish. and mechanical stability having X and Y thermal Commonly used storage procedures used to control coefficient of expansion (CTE) of 17-25 ppm/oC. oxidation should be followed for these surface mount components. The storage temperatures should be held When a surface mount hybrid coupler is mounted to a between 15OC and 60OC. printed circuit board, the primary concerns are; ensuring the RF pads of the device are in contact with the circuit Substrate: Depending upon the particular component, trace of the PCB and insuring the ground plane of neither the circuit material has an x and y coefficient of thermal the component nor the PCB is in contact with the RF expansion of between 17 and 25 ppm/°C. This coefficient signal. minimizes solder joint stresses due to similar expansion rates of most commonly used board substrates such as Mounting Footprint RF35, RO4350, FR4, polyimide and G-10 materials. Mounting to “hard” substrates (alumina etc.) is possible depending upon operational temperature requirements. The solder surfaces of the coupler are all copper plated with either an immersion tin or tin-lead exterior finish. Solder Paste: All conventional solder paste formulations will work well with Anaren’s Xinger III surface mount components. Solder paste can be applied with stencils or syringe dispensers. An example of a stenciled solder paste deposit is shown in Figure 2. As shown in the figure solder paste is applied to the four RF pads and the entire ground plane underneath the body of the part. USA/Canada: (315) 432-8909 Available on Tape and Toll Free: (800) 411-6596 Reel for Pick and Place Europe: +44 2392-232392 Manufacturing.
Model X3C09P2-30S Rev C Reflow: The surface mount coupler is conducive to most of today’s conventional reflow methods. A low and high temperature thermal reflow profile are shown in Figures 5 and 6, respectively. Manual soldering of these components can be done with conventional surface mount non-contact hot air soldering tools. Board pre-heating is highly recommended for these selective hot air soldering methods. Manual soldering with conventional irons should be avoided. Figure 2: Solder Paste Application Coupler Positioning: The surface mount coupler can be placed manually or with automatic pick and place mechanisms. Couplers should be placed (see Figure 3 and 4) onto wet paste with common surface mount techniques and parameters. Pick and place systems must supply adequate vacuum to hold a 0.204 gram coupler. Figure 3: Component Placement Figure 4: Mounting Features Example Available on Tape USA/Canada: (315) 432-8909 and Reel for Pick and Toll Free: (800) 411-6596 Place Manufacturing. Europe: +44 2392-232392
Model X3C09P2-30S Rev C Figure 5 – Low Temperature Solder Reflow Thermal Profile Figure 6 – High Temperature Solder Reflow Thermal Profile USA/Canada: (315) 432-8909 Available on Tape and Toll Free: (800) 411-6596 Reel for Pick and Place Europe: +44 2392-232392 Manufacturing.
Model X3C09P2-30S Rev C Qualification Flow Chart Xinger III Product Qualificatio n Visual Inspection n=55 Solderability Test n=5 Mechanicna=l 5I0ns pection Initial RF Test n=50 Visual Inspection n=50 Loose Control Units V-TEK Testing n=5 n=45 Visual Inspection n=50 Post V-TEK Test RF Test n=50 Loose Control Units Visual Inspection n=5 n=50 Resistance to Solder MIL 202G Solder Units to Test Post Solder Visual Method 210F, Condition K Heat Board Inspection n=20 n=25 n=25 Post Resistance Heat RF Initial RF Test Board Test Mounted n=20 n=25 Control Units RF Test Visual Inspection 25°C only n=25 Loose Cno=n5tr ol Units Mechanicna=l2 I0n spection n= 5 RF Test at -55°C, 25°C, 95°C n=20 Voltage Breakdown Test MIL Visual Inspection 202F, Method 301 25°C 5KV n=25 n=40 Visual Inspection Control Units n=50 n=5 Available on Tape USA/Canada: (315) 432-8909 and Reel for Pick and Toll Free: (800) 411-6596 Place Manufacturing. Europe: +44 2392-232392
Model X3C09P2-30S Rev C Control Units Post Voltage RF Test n=10 n=50 Thermal Cycle100 cycles -55° to 125°C. Dwell time= 30 min n=40 Visual Inspection n=50 Post Thermal RF Test Control Units n=50 n=10 Moisture Resistance Testing -25° to 65°C for 2 hrs @ 90% humidity. Soak for 168 hrs at 90% to 85% humidity. Ramp temp to 25°C in 2 hrs @ 90% humidity. Then soak @ -10°C for 3 hrs. n=40 Post Moisture Resistance RF Test n=50 Post Moisture Resistance RF Test n=50 Conntr=o1l 0U nits Visualn I=ns5p0 ection Bake Units for 1 hour at 100° to 120°C n=40 Post Bake RF Test n=50 Visual Inspection n=30 125% Power Life Test 72 hrs n=3 Final RF Test @ 25°C n=25 Microsection 3 test units 1 control Microsection 2 Life, 1 high power and 1 control USA/Canada: (315) 432-8909 Available on Tape and Toll Free: (800) 411-6596 Reel for Pick and Place Europe: +44 2392-232392 Manufacturing.
Model X3C09P2-30S Rev C Application Information Directional Couplers and Sampling Directional couplers are often used in circuits that require the sampling of an arbitrary signal. Because they are passive, non-linear devices, Anaren directional couplers do not perturb the characteristics of the signal to be sampled, and can be used for frequency monitoring and/or measurement of RF power. An example of a sampling circuit is the reflectometer. The purpose of the reflectometer is to isolate and sample the incident and reflected signals from a mismatched load. A basic reflectometer circuit is shown in Figure ap.n.1-1. V input 1 2 LOAD Reflected Wave 4 3 V V I R Figure ap.n.1-1. A Reflectometer Circuit Schematic If the directional coupler has perfect directivity, then it is clear that V is strictly a sample of the incident voltage V , I input and V is strictly a sample of the wave that is reflected from the load. Since directivity is never perfect in practice, both R V and V will contain samples of the input signal as well as the reflected signal. In that case, I R V C CDTej I Eq. ap.n.1-1 and V CD CTej R Eq. ap.n.1-2 where C is the coupling, D is the directivity, is the complex reflection coefficient of the load, T is the transmission coefficient, and and are unknown phase delay differences caused by the interconnect lines on the test board. If we know V and V , we can easily calculate the reflection coefficient of the load. One should notice that in order to make I R forward and reverse measurements using only one coupler, the directivity must be really low. In specific customer applications, the preferred method for forward and reverse sampling is shown in Figure ap.n.1-2. Available on Tape USA/Canada: (315) 432-8909 and Reel for Pick and Toll Free: (800) 411-6596 Place Manufacturing. Europe: +44 2392-232392
Model X3C09P2-30S Rev C ISOLATOR INPUT 1 2 LOAD Reflected Wave 4 3 FORWARD MEASUREMENT REVERSE **TERMINATION MEASUREMENT *Recommended Terminations Power (Watts) Model 8 RFP- 060120A15Z50-2 10 RFP- C10A50Z4 16 RFP- C16A50Z4 20 RFP- C20N50Z4 50 RFP- C50A50Z4 100 RFP- C100N50Z4 200 RFP- C200N50Z4 Figure ap.n.1-2. Forward and Reverse Sampling The isolator in Figure ap.n.1-2 prevents the reflected wave from exciting the directional coupler. A list of recommended terminations is shown in the figure. Directional Couplers in Feed-Forward Amplifier Applications Feed-forward amplifiers are widely used to reduce distortion due to nonlinearities in power amplifiers. Although the level and complexity of feed-forward amplifiers varies from one manufacturer to another, the basic building block for this linearization scheme remains the same. A basic feed-forward schematic is shown in Figure ap.n.2-1. The input signal is split in two using a hybrid coupler or power divider. The output of the main amplifier is sampled with a 20dB-30dB directional coupler. The X3C09P2-30S is an excellent candidate for this sampling since it provides great return loss and directivity. The sampled signal, which consists of a sample of the original input signal plus some distortion, is inverted and then combined with the output of the first delay line. This procedure subtracts (through destructive interference) the sample of the original input signal, leaving only the distortion or error component. The error component is then amplified and combined with the output of the second delay line using another directional coupler. In many cases, a 10dB coupler is used to combine the two signals. The XC0900E-10 is a perfect choice for this injection because it has tight coupling, superior directivity, and excellent match. USA/Canada: (315) 432-8909 Available on Tape and Toll Free: (800) 411-6596 Reel for Pick and Place Europe: +44 2392-232392 Manufacturing.
Model X3C09P2-30S Rev C *Recommended Terminations Power (Watts) Model 8 RFP- 060120A15Z50-2 10 RFP- C10A50Z4 16 RFP- C16A50Z4 20 RFP- C20N50Z4 50 RFP- C50A50Z4 100 RFP- C100N50Z4 200 RFP- C200N50Z4 Figure ap.n.2-1. Generic Feed Forward Circuit Schematic Both directional couplers in the Figure ap.n.2-1 have one port terminated with a 50 resistor. In order to achieve optimum performance, the termination must be chosen carefully. It is important to remember that a good termination will not only produce a good match at the input of the coupler, but will also maximize the isolation between the input port and isolated port. Furthermore, since the termination can potentially absorb high levels of power, its maximum power rating should be chosen accordingly. A list of recommended terminations is shown in Figure ap.n.2-1. For an ideal lossless directional coupler, the power at the coupled and direct ports can be written as: P input P Watts coupled Coupling(dB) Eq. ap.n.2-1 10 10 P P P input Watts direct input Coupling(dB) Eq. ap.n.2-2 10 10 where P is the input power in Watts, and Coupling(dB) is the coupling value in dB. input Available on Tape USA/Canada: (315) 432-8909 and Reel for Pick and Toll Free: (800) 411-6596 Place Manufacturing. Europe: +44 2392-232392
Model X3C09P2-30S Rev C Packaging and Ordering Information Parts are available in a reel and as loose parts in a bag. Packaging follows EIA 481-D for reels. Parts are oriented in tape and reel as shown below. Minimum order quantities are 2000 per reel. See Model Numbers below for further ordering information. XXX XX X X - XX X Xinger Coupler Frequency (MHz) Size (Inches) Power (Watts) Coupling Value Plating Finish 04 = 410-500 A = 0.56 x 0.35 1 = 100 03 = 3dB P = Tin Lead 07 = 600-900 B = 1.0 x 0.50 2 = 200 05 = 5dB S = Immersion Tin 09 = 800-1000 E = 0.56 x 0.20 3 = 300 10 = 10dB X3C 19 = 1700-2000 L = 0.65 x 0.48 20 = 20dB 21 = 2000-2300 M= 0.40 x 0.20 30 = 30dB 25 = 2300-2500 P = 0.25 x 0.20 26 = 2650-2800 35 = 3300-3800 Example: X3C 19 P 1 - 03 S USA/Canada: (315) 432-8909 Available on Tape and Toll Free: (800) 411-6596 Reel for Pick and Place Europe: +44 2392-232392 Manufacturing.
Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: A naren: X3C09P2-30S