图片仅供参考

详细数据请看参考数据手册

Datasheet下载
  • 型号: PMC-12V100W1AA
  • 制造商: DELTA PRODUCTS CORPORATION
  • 库位|库存: xxxx|xxxx
  • 要求:
数量阶梯 香港交货 国内含税
+xxxx $xxxx ¥xxxx

查看当月历史价格

查看今年历史价格

PMC-12V100W1AA产品简介:

ICGOO电子元器件商城为您提供PMC-12V100W1AA由DELTA PRODUCTS CORPORATION设计生产,在icgoo商城现货销售,并且可以通过原厂、代理商等渠道进行代购。 提供PMC-12V100W1AA价格参考以及DELTA PRODUCTS CORPORATIONPMC-12V100W1AA封装/规格参数等产品信息。 你可以下载PMC-12V100W1AA参考资料、Datasheet数据手册功能说明书, 资料中有PMC-12V100W1AA详细功能的应用电路图电压和使用方法及教程。

产品参数 图文手册 常见问题
参数 数值
2D图纸

http://www.deltapsu.com/upload/product_image/48_20130401_015852520_PMC-12V100W1AA.dxf.zip

3D型号

http://www.deltapsu.com/upload/product_image/48_48_20130401_015852520_PMC-12V100W1AA%20(EOE11010187)%203D%20Rev.%2000.stp.zip

产品目录

电源 - 外部/内部(外接)

描述

POWER SUPPLY PANEL MT 100W 12VDC

产品分类

AC DC 转换器

品牌

Delta Electronics

数据手册

点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet

产品图片

产品型号

PMC-12V100W1AA

rohs

无铅 / 符合限制有害物质指令(RoHS)规范要求

产品系列

PMC

产品培训模块

http://www.digikey.cn/PTM/IndividualPTM.page?site=cn&lang=zhs&ptm=26201

产品目录页面

点击此处下载产品Datasheet

其它名称

603-1240
PMC12V100W1AA

其它有关文件

点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet

功率(W)

100W

功率(W)-最大值

100W

大小/尺寸

6.22" 长 x 3.82" 宽 x 1.50" 高(158.0mm x 97.0mm x 38.0mm)

安装类型

底座安装

工作温度

-10°C ~ 70°C

应用

ITE(商业)

所需最小负载

-

效率

84%

标准包装

1

特性

可调输出,通用输入

特色产品

http://www.digikey.com/cn/zh/ph/Delta/PMCseries.htmlhttp://www.digikey.cn/product-highlights/cn/zh/delta-power-mgmt-acdc-industrial/3751

电压-输入

85 ~ 264 VAC

电压-输出1

12V

电压-输出2

-

电压-输出3

-

电压-输出4

-

电压-隔离

3kV(3000V)

电流-输出(最大值)

8.33A

类型

封闭式

认可

CCC, CE, cURus

输出数

1

推荐商品

型号:IPL60R650P6SATMA1

品牌:Infineon Technologies

产品名称:分立半导体产品

获取报价

型号:MC33291DWR2

品牌:NXP USA Inc.

产品名称:集成电路(IC)

获取报价

型号:HMC1056LP4BE

品牌:Analog Devices Inc.

产品名称:射频/IF 和 RFID

获取报价

型号:1200650419

品牌:Molex, LLC

产品名称:电缆组件

获取报价

型号:0638117575

品牌:Molex, LLC

产品名称:工具

获取报价

型号:STD18NF03L

品牌:STMicroelectronics

产品名称:分立半导体产品

获取报价

型号:BD437S

品牌:ON Semiconductor

产品名称:分立半导体产品

获取报价

型号:87381-108HLF

品牌:None

产品名称:连接器,互连器件

获取报价

样品试用

万种样品免费试用

去申请
PMC-12V100W1AA 相关产品

MHMD022G1S

品牌:Panasonic Industrial Automation Sales

价格:

SMR-02V-N

品牌:JST Sales America Inc.

价格:

DS36C278M/NOPB

品牌:Texas Instruments

价格:

HFBR-1531Z

品牌:Broadcom Limited

价格:

HR30-6JA-6P(71)

品牌:Hirose Electric Co Ltd

价格:¥34.38-¥34.38

3-640599-2

品牌:TE Connectivity AMP Connectors

价格:¥1.06-¥2.23

FJPF5027RTU

品牌:ON Semiconductor

价格:

SSRK-600A30

品牌:TE Connectivity Potter & Brumfield Relays

价格:¥440.69-¥495.24

PDF Datasheet 数据手册内容提取

T ECHNICAL DATASHEET PMC Panel Mount Power Supply 12V 100W 1 Phase / PMC-12V100W1A□ PMC Highlights & Features  Universal AC input voltage range  Power will not de-rate for the entire input voltage range  Full corrosion resistant aluminium casing  Conforms to harmonic current IEC/EN 61000-3-2, Class A  High MTBF > 700,000 hrs per Telcordia SR-332  Safety approval according to IEC/EN/UL 60950-1 (ITE standard) and EMI to EN 55022, Class B Safety Standards CB Certified for worldwide use Model Number: PMC-12V100W1A☐ Unit Weight: 0.45 kg (0.99 lb) Dimensions (L x W x D): 158 x 97x 38 mm (6.22 x 3.82 x 1.50 inch) General Description The new Panel Mount Power Supply is the latest offering from one of the world’s largest power supply manufacturers and solution providers - Delta. The product range offers a nominal output voltage of 12V, a wide temperature range from -10°C to +70°C and a highly dependable minimum holdup time. The state-of-the-art design is made to withstand harsh industrial environments. What makes the product stands out from the crowd is its lightweight full aluminum body design which can withstand shock and vibration according to IEC 60068-2. Delta’s Panel Mount Power Supply also offers overvoltage and overload protection. Using a wide input voltage range design, it is compatible worldwide. The input also includes DC operating voltage from 125-375Vdc. Best of all, this excellent design and quality does not come with a big price tag. Model Information PMC Panel Mount Power Supply Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMC-12V100W1A□ 85-264Vac (125-375Vdc) 12Vdc 8.34A Model Numbering PM C – 12V 100W 1 A Panel Mount Product Type Output Voltage Output Power Single Phase No PFC Connector Type C – Enclosed A – Terminal Block J – IP20 Connector* L – Front Face* H – Harness* *Options A J L H All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 1 www.DeltaPSU.com (November 2018, Rev. 04)

T ECHNICAL DATASHEET PMC Panel Mount Power Supply 12V 100W 1 Phase / PMC-12V100W1A□ Specifications Input Ratings / Characteristics Nominal Input Voltage 100-240Vac Input Voltage Range 85-264Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Nominal DC Input Voltage 125-250Vdc DC Input Voltage Range* 125-375Vdc Input Current < 2.0A @ 115Vac, < 1.1A @ 230Vac Efficiency at 100% Load > 84% @ 115Vac, > 86% @ 230Vac Max Power Dissipation 0% load < 1.5W @ 115Vac & 230Vac 100% load < 18.5W @ 115Vac, < 15W @ 230Vac Max Inrush Current (Cold Start) < 60A @ 115Vac, < 130A @ 230Vac Leakage Current < 1mA @ 240Vac *Safety approval according to IEC/EN/UL 60950-1. Output Ratings / Characteristics** Nominal Output Voltage 12Vdc Factory Set Point Tolerance 12Vdc ± 2% Output Voltage Adjustment Range 11-14Vdc Output Current 8.34A (100W max.) Output Power 100W Line Regulation < 0.5% typ. (@ 85-264Vac input, 100% load) Load Regulation < 1% typ. (@ 85-264Vac input, 0-100% load) PARD*** (20MHz) < 100mVpp Rise Time < 30ms @ nominal input (100% load) Start-up Time < 1000ms @ nominal input (100% load) Hold-up Time > 15ms @ 115Vac (100% load) > 80ms @ 230Vac (100% load) Dynamic Response ± 5% @ 85-264Vac, 0-100% load (Overshoot & Undershoot O/P Voltage) (Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz) Start-up with Capacitive Loads 8,000µF Max **For power de-rating from 50°C to 70°C, see power de-rating on page 3. ***PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1µF ceramic capacitor & 47µF electrolytic capacitor. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 2 www.DeltaPSU.com (November 2018, Rev. 04)

T ECHNICAL DATASHEET PMC Panel Mount Power Supply 12V 100W 1 Phase / PMC-12V100W1A□ Mechanical Case Chassis / Cover Aluminium Dimensions (L x W x D) 158 x 97 x 38 mm (6.22 x 3.82 x 1.50 inch) Unit Weight 0.45 kg (0.99 lb) Indicator Green LED (DC OK) Cooling System Convection Terminal PMC-12V100W1AA M3.5 x 7 Pins (Rated 300V/15A) PMC-12V100W1AJ M3.5 x 7 Pins (Rated 300V/20A) PMC-12V100W1AL M3.5 x 7 Pins (Rated 300V/20A) PMC-12V100W1AH Input: B3P(6-2.3.5)-VH(LF)(SN) Output: B4P7-VH(LF)(SN) Wire PMC-12V100W1AA AWG 22-14 PMC-12V100W1AJ AWG 22-12 PMC-12V100W1AL AWG 22-12 PMC-12V100W1AH AWG 22-18 Noise (1 Meter from power supply) Sound Pressure Level (SPL) < 40dBA Environment Surrounding Air Temperature Operating -10°C to +70°C Storage -25°C to +85°C Power De-rating > 50°C de-rate power by 2.5% / °C Operating Humidity 5 to 95% RH (Non-Condensing) Operating Altitude 0 to 3,000 Meters (9,840 ft.) Shock Test Non-Operating IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms 1 times per direction, 6 times in total Vibration Non-Operating IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); 20 min per axis for all X, Y, Z direction Over Voltage Category II Pollution Degree 2 Protections Overvoltage 16V +10%/-5%, SELV output, Hiccup Mode, Non-Latching (Auto recovery) Overload / Overcurrent > 120% of rated load current, Hiccup Mode, Non-Latching (Auto recovery) Over Temperature < 75°C Ambient Temperature @ 100% load, Non-Latching (Auto-recovery) Short Circuit Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed) Internal Fuse at L pin T3.15AH Degree of Protection IP20 (PMC-12V100W1AJ) Protection Against Shock Class I with PE* connection *PE: Primary Earth All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 3 www.DeltaPSU.com (November 2018, Rev. 04)

T ECHNICAL DATASHEET PMC Panel Mount Power Supply 12V 100W 1 Phase / PMC-12V100W1A□ Reliability Data MTBF > 700,000 hrs, as per Telcordia SR-332 I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C Expected Cap Life Time 10 years (115Vac & 230Vac, 50% load and 40°C) Safety Standards / Directives Safety Entry Low Voltage SELV (EN 60950-1) Electrical Safety TUV Bauart EN 60950-1 UL/cUL UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) CB Scheme IEC 60950-1 CCC GB4943 CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input to Output 3.0 KVac Input to Ground 1.5 KVac Output to Ground 500 Vac EMC Emissions (CE & RE) CISPR 32, EN 55032, FCC Title 47: Class B, GB9254 Immunity Generic Standards: EN 55024 Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1) Air Discharge: 15kV Contact Discharge: 8kV Radiated Field IEC 61000-4-3 Level 3 Criteria A1) 80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1) 2kV Surge IEC 61000-4-5 Level 3 Criteria A1) Common Mode2): 2kV Differential Mode3): 2kV Conducted IEC 61000-4-6 Level 3 Criteria A1) 150kHz-80MHz, 10Vrms Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A1) 10A/Meter Voltage Dips and Interruptions IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable Low Energy Pulse Test (Ring Wave) IEC 61000-4-12 Level 3 Criteria A1) Common Mode2): 2kV Differential Mode3): 1kV Harmonic Current Emission IEC/EN 61000-3-2, Class A Voltage Fluctuation and Flicker IEC/EN 61000-3-3 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 4 www.DeltaPSU.com (November 2018, Rev. 04)

T ECHNICAL DATASHEET PMC Panel Mount Power Supply 12V 100W 1 Phase / PMC-12V100W1A□ Block Diagram Device Description PMC-12V100W1AA: Terminal Block PMC-12V100W1AJ: IP20 Connector PMC-12V100W1AL: Front Face PMC-12V100W1AH: Harness 1) Input & Output terminal block connector 2) DC Voltage adjustment potentiometer 3) DC OK control LED (Green) All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 5 www.DeltaPSU.com (November 2018, Rev. 04)

T ECHNICAL DATASHEET PMC Panel Mount Power Supply 12V 100W 1 Phase / PMC-12V100W1A□ Dimensions L x W x D: 158 x 97 x 38 mm (6.22 x 3.82 x 1.50 inch) (PMC-12V100W1AA: Terminal Block) Engineering Data Output Load De-rating VS Surrounding Air Temperature Note 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when the surrounding air temperature exceeds its specification as defined on Page 3 under “Environment”, the device may run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3. In order for the device to function in the manner intended, it is also necessary to keep a safety distance as recommended in the safety instructions while the device is in operation. 4. Depending on the surrounding air Fig. 1 De-rating for Vertical and Horizontal Mounting Orientation temperature and output load delivered by the > 50°C de-rate power by 2.5% / °C power supply, the device housing can be very hot! 5. If the device has to be mounted in any other orientation, please contact info@deltapsu.com for more details. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 6 www.DeltaPSU.com (November 2018, Rev. 04)

T ECHNICAL DATASHEET PMC Panel Mount Power Supply 12V 100W 1 Phase / PMC-12V100W1A□ Output Load De-rating VS Input Voltage  No output power de-rating across the entire input voltage range Assembly & Installation Mounting Ⓐ Mounting holes for power supply assembly onto the mounting surface. Power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5 mm (0.20 inch) length. Ⓑ This surface belongs to customer’s end system or panel where the power supply is mounted. Ⓒ Connector. Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal) Fig. 2 Mounting Orientation  Use flexible cable (stranded or solid) with the following sizes: PMC-12V100W1AA PMC-12V100W1AJ PMC-12V100W1AL AWG 22-14 AWG 22-12 AWG 22-12  PMC-12V100W1AA / PMC-12V100W1AJ / PMC-12V100W1AL: The torque at the Connector shall not exceed 13 Kgf.cm (11.23 lbf.in). The insulation stripping length should not exceed 0.275” or 7 mm.  PMC-12V100W1AH: Please refer the table below for the recommended mating connector, terminal and AWG wire size. Power Supply Header Mating Connector Terminal AWG Input (JST) B3P(6-2.3.5)-VH(LF)(SN) VHR-6N SVH-21T-P1.1 22-18 Output (JST) B4P7-VH(LF)(SN) VHR-7N SVH-21T-P1.1 22-18 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 7 www.DeltaPSU.com (November 2018, Rev. 04)

T ECHNICAL DATASHEET PMC Panel Mount Power Supply 12V 100W 1 Phase / PMC-12V100W1A□ Installation of Mounting Accessories  Only use M3 screw ≤ 6 mm (0.24 inch) through the base mounting holes. This is to keep a safety distance between the screw and internal components.  Recommended mounting tightening torque: 4~8Kgf.cm (3.47~6.94 lbf.in). Safety Instructions  To ensure sufficient convection cooling, always maintain a safety distance of > 20 mm (0.79 inch) from all ventilated surfaces while the device is in operation.  The device is not recommended to be placed on low thermal conductive surface, for example, plastics.  Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning!  Do not touch the terminals while power is being supplied. Risk of electric shock.  Prevent any foreign metal, particles or conductors to enter the device through the openings during installation. It can cause: - - Electric shock; Safety Hazard; Fire; Product failure  Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. Accessories L-02: Latch P-03: Bracket These accessories are used to mount the panel mount power supply onto a DIN rail. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 8 www.DeltaPSU.com (November 2018, Rev. 04)

T ECHNICAL DATASHEET PMC Panel Mount Power Supply 12V 100W 1 Phase / PMC-12V100W1A□ Functions  Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value. Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value. Inrush Current Dynamic Response Inrush current is the peak, instantaneous, input current measured The power supply output voltage will remains within ±5% of its and, occurs when the input voltage is first applied. For AC input steady state value, when subjected to a dynamic load from 0% to voltages, the maximum peak value of inrush current will occur 100%. during the first half cycle of the applied AC voltage. This peak value  50% duty cycle / 5Hz decreases exponentially during subsequent cycles of AC voltage. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 9 www.DeltaPSU.com (November 2018, Rev. 04)

T ECHNICAL DATASHEET PMC Panel Mount Power Supply 12V 100W 1 Phase / PMC-12V100W1A□ Overload & Overcurrent Protections (Auto-Recovery) Overvoltage Protection (Auto-Recovery) The power supply’s Overload (OLP) and Over current (OCP) The power supply’s overvoltage circuit will be activated when its Protections will be activated when output current (IO) exceeds its internal feedback circuit fails. The output voltage shall not exceed specification as defined on Page 3 under “Protections. In such its specifications defined on Page 3 under “Protections”. occurrence, the output voltage (VO) will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto- Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. Over Temperature Protection (Auto-Recovery) As described in load de-rating section, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de-rating It is not recommended to prolong the duration of IO when it is less graph. than OLP/OCP point, but greater than100%, since it may cause damage to the PSU. Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 1 0 www.DeltaPSU.com (November 2018, Rev. 04)

T ECHNICAL DATASHEET PMC Panel Mount Power Supply 12V 100W 1 Phase / PMC-12V100W1A□ Operating Mode  Parallel Operation The power supply units (PSUs) can also be used for parallel operation in order to increase the output power. The difference in output voltage between the two units must be kept to within 25mV of each other. This difference must be verified with the same output load connected independently to each unit. Parameters such as EMI, inrush current, leakage current, PARD, start up time will be different from those on the datasheet, when two units are connected in parallel. The user will need to verify that any differences will still allow the two power supplies connected in parallel will work properly in their product/application. Fig. 3 Parallel Operation Connection Diagram Fig. 4 DC Input Operation Connection Diagram  DC Input Operation Step 1. Use a battery or similar DC source. Step 2. Connect +pole to L and -pole to N. Step 3. Connect the PE terminal to an earth wire or to the machine ground. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 1 1 www.DeltaPSU.com (November 2018, Rev. 04)

T ECHNICAL DATASHEET PMC Panel Mount Power Supply 12V 100W 1 Phase / PMC-12V100W1A□ Fig. 5 2 of 3 Phase System Input Operation Connection Diagram  2 of 3 Phase System Input Operation Delta's PMC can use on 2 of 3 phase system. Please refer to the following step. Step 1. The input voltage applied from Line to Neutral is below the maximum rated input. The input voltage shall be below 240Vac +10%. Step 2. The external protector is needed on N (Neutral) input line to secure a safety. N line does not have internal fuse protection. An appropriate fuse or circuit breaker should be connected in series with N input line connection like the following. Others Delta RoHS Compliant Restriction of the usage of hazardous substances The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in electrical and electronic equipment”. This product conforms to this standard. PFC – Norm EN 61000-3-2 Line Current Harmonic content Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs, Frequently, the user does not profit form fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific application. Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 1 2 www.DeltaPSU.com (November 2018, Rev. 04)

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: D elta Electronics: PMC-12V100W1AA