图片仅供参考

详细数据请看参考数据手册

Datasheet下载
  • 型号: NMR101C
  • 制造商: Murata
  • 库位|库存: xxxx|xxxx
  • 要求:
数量阶梯 香港交货 国内含税
+xxxx $xxxx ¥xxxx

查看当月历史价格

查看今年历史价格

NMR101C产品简介:

ICGOO电子元器件商城为您提供NMR101C由Murata设计生产,在icgoo商城现货销售,并且可以通过原厂、代理商等渠道进行代购。 NMR101C价格参考。MurataNMR101C封装/规格:直流转换器, 隔离模块 DC/DC 转换器 1 输出 12V 83mA 4.5V - 5.5V 输入。您可以下载NMR101C参考资料、Datasheet数据手册功能说明书,资料中有NMR101C 详细功能的应用电路图电压和使用方法及教程。

产品参数 图文手册 常见问题
参数 数值
产品目录

电源 - 板安装

描述

CONV DC/DC 1W 5VIN 12V SIP SGL隔离式DC/DC转换器 1W SNGL OUT 5-12V Single Output

产品分类

DC DC ConvertersDC/DC转换器

品牌

Murata Power Solutions

产品手册

点击此处下载产品Datasheet

产品图片

rohs

RoHS 合规性豁免无铅 / 符合限制有害物质指令(RoHS)规范要求

产品系列

隔离式DC/DC转换器,Murata Power Solutions NMR101CNMR

数据手册

点击此处下载产品Datasheet

产品型号

NMR101C

产品

Isolated

产品培训模块

http://www.digikey.cn/PTM/IndividualPTM.page?site=cn&lang=zhs&ptm=21791

产品目录页面

点击此处下载产品Datasheet

产品种类

隔离式DC/DC转换器

其它名称

811-1567-5

功率(W)-制造系列

1W

功率(W)-最大值

1W

包装

管件

商标

Murata Power Solutions

大小/尺寸

0.77" 长 x 0.24" 宽 x 0.39" 高(19.6mm x 6.1mm x 9.9mm)

安装类型

通孔

封装

Tube

封装/外壳

7-SIP 模块(4 引线)

封装/箱体尺寸

SIP-7

工作温度

-40°C ~ 85°C

工厂包装数量

25

效率

77%

标准包装

25

特性

-

电压-输入(最大值)

5.5V

电压-输入(最小值)

4.5V

电压-输出1

12V

电压-输出2

-

电压-输出3

-

电压-隔离

1kV(1000V)

电流-输出(最大值)

83mA

类型

隔离模块

系列

NMR

绝缘电压

1 kV

输入电压—公称值

5 V

输入电压范围

4.5 V to 5.5 V

输出功率

1 W

输出数

1

输出电压—通道1

12 V

输出电流—通道1

83 mA

输出端数量

1

推荐商品

型号:R1D-153.3/HP-R

品牌:Recom Power

产品名称:电源 - 板安装

获取报价

型号:V24A24T300BG2

品牌:Vicor Corporation

产品名称:电源 - 板安装

获取报价

型号:JCB0324D12

品牌:XP Power

产品名称:电源 - 板安装

获取报价

型号:RK-1215S/H

品牌:Recom Power

产品名称:电源 - 板安装

获取报价

型号:TEN 3-4813WIN

品牌:Traco Power

产品名称:电源 - 板安装

获取报价

型号:R0.5D-0505/HP

品牌:Recom Power

产品名称:电源 - 板安装

获取报价

型号:VI-J01-IY-B1

品牌:Vicor Corporation

产品名称:电源 - 板安装

获取报价

型号:LMZ12001TZX-ADJ/NOPB

品牌:Texas Instruments

产品名称:电源 - 板安装

获取报价

样品试用

万种样品免费试用

去申请
NMR101C 相关产品

UIQ48T72033-NDABG

品牌:Bel Power Solutions

价格:¥273.01-¥273.01

VI-263-IX-F2

品牌:Vicor Corporation

价格:

PAH300S4812/PT

品牌:TDK-Lambda Americas Inc.

价格:

PXB15-24WS12/NT

品牌:TDK-Lambda Americas Inc.

价格:¥352.64-¥365.38

REC5-2405SRWZ/H2/A/M/CTRL

品牌:Recom Power

价格:

ISA0512

品牌:XP Power

价格:¥30.24-¥30.24

TPS84620RUQT

品牌:Texas Instruments

价格:¥54.19-¥65.03

ATA010A0X3Z

品牌:GE Critical Power

价格:

PDF Datasheet 数据手册内容提取

NMR Series www.murata-ps.com Isolated 1W Single Output DC/DC Converters SELECTION GUIDE Order Code Nominal Input VoltageOutput Voltage Output Current Input Current at Rated Load Load Regulation Ripple & Noise3 Efficiency (Min)Efficiency (Typ)Isolation Capacitance MTTF1 % mV p-p MIL. Tel. V V mA mA % pF Typ. Max. Typ. Max. kHrs NMR100C 5 5 200 290 12 14 6 10 69 28 1847 FEATURES NMR101C 5 12 83 260 6.9 7.7 4.6 10 77 33 981 NMR102C 5 15 67 253 6.5 7.5 4.3 10 79 40 667 (cid:132)(cid:3)Short circuit protection option NMR106C 12 5 200 121 12.5 13.4 5.3 10 69 36 1485 (cid:132)(cid:3)UL 60950 recognised NMR107C 12 12 83 110 6.9 7.7 5 10 76 58 869 (cid:132)(cid:3)1kVDC isolation ‘Hi Pot Test’ NMR108C 12 15 67 110 6.5 7.5 4 10 76 56 613 NMR118C 24 5 200 60 6.8 10 8 15 70 61 1253 (cid:132)(cid:3)Wide temperature performance at full NMR119C 24 12 83 53 2.8 4 7 15 78 98 784 1 watt load, –40°C to 85°C NMR120C 24 15 67 52 2.5 3.5 8 15 80 122 566 (cid:132)(cid:3)Industry standard pinout Short Circuit Protection Option NMR100PC 5 5 200 255 10 12 10 25 74 76.5 22 3095 61060 (cid:132)(cid:3)5V, 12V & 24V input Recommended Alternative (cid:132)(cid:3)5V, 12V & 15V output NMR112C 15 5 200 93 8.1 10 14 20 69 27 2110 MER1S1505SC (cid:132)(cid:3)Fully encapsulated with toroidal magnetics NMR113C 15 12 83 85 3.3 4 12 15 77 58 1790 MER1S1512SC NMR114C 15 15 67 84 2.8 3.5 14 20 78 67 1560 MER1S1515SC (cid:132)(cid:3)Custom solutions available INPUT CHARACTERISTICS (cid:132)(cid:3)No electrolytic or tantalum capacitors Parameter Conditions Min. Typ. Max. Units Continuous operation, 5V input types 4.5 5 5.5 DESCRIPTION Continuous operation, 12V input types 10.8 12 13.2 The NMR series of industrial temperature range Voltage range Continuous operation, 15V input types 13.5 15 16.5 V DC/DC converters are the standard building Continuous operation, 24V input types 21.6 24 26.4 blocks for on-board distributed power systems. Input short circuit current Short circuit variants 95 mA They are ideally suited for providing single rail Short circuit types 2 15 supplies on primarily digital boards with the added Input reflected ripple 5V & 12V input types 1.6 2 mA p-p benefit of galvanic isolation to reduce switching current 15V & 24V input types 5 10 noise. Surface mount technology and advanced packaging materials produce rugged reliable OUTPUT CHARACTERISTICS performance over an extended temperature range Parameter Conditions Min. Typ. Max. Units from -40ºC to 85ºC. For the NMR100PC protection Rated Power2 TA=-40°C to 85°C, See derating graph 1.0 W is continuous and auto-resetting on removal of the Voltage Set Point Accuracy See tolerance envelope short circuit. High VIN to low VIN ; Short circuit types 1.15 1.2 Line regulation %/% High VIN to low VIN ; All other output types 1.0 1.2 ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation voltage Flash tested for 1 second 1000 VDC Resistance Viso=1000VDC 10 GΩ ABSOLUTE MAXIMUM RATINGS Lead temperature 1.5mm from case for 10 seconds 260°C Input voltage VIN, NMR100C, NMR101C, NMR102C 7V Input voltage VIN, NMR106C, NMR107C, NMR108C 15V Input voltage VIN, NMR112C, NMR113C, NMR114C 18V Input voltage VIN, NMR118C, NMR119C, NMR120C 28V 1. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load. 2. See derating graph. For full details go to 3. See ripple & noise characterisation method. www.murata-ps.com/rohs All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com/support KDC_NMR.F01 Page 1 of 10

NMR Series Isolated 1W Single Output DC/DC Converters GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 5V input types 110 12V input types 160 Switching frequency 15V input types 90 kHz 24V input types 80 Short circuit types 97 TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Specification All output types -40 85 Storage -50 130 5V output types 33 °C Case Temperature above ambient All other output types 28 Short circuit types 18 Cooling Free air convection TOLERANCE ENVELOPES NMR118 NMR113, NMR 114, NMR119, NMR120 +7% +4% +2% age VNOM 0% age VNOM +1% Volt Volt -3% ut -5% ut p p ut ut O 10 25 50 75 100 O 10 25 50 75 100 Output Load Current (%) Output Load Current (%) All other output types: Short circuit types: +10% +10% +5% +2.5% e e g g a a olt V olt V 0% V NOM V NOM ut ut p p ut ut -6% O -7.5% O 10 25 50 75 100 10 25 50 75 100 Output Load Current (%) Output Load Current (%) The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading. www.murata-ps.com/support KDC_NMR.F01 Page 2 of 10

NMR Series Isolated 1W Single Output DC/DC Converters TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NMR series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” The NMR is recognised by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NMR series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL UL60950 The NMR series is recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum still air ambient temperature of 100°C as measured at any point on the case of the unit (hotspot). FUSING The NMR Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as defined below. Input Voltage, 5V 0.5A Input Voltage, 12V 0.25A Input Voltage, 24V 0.12A All fuses should be UL recognized, 125V rated. File number E151252 applies. RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC for 10 seconds. The pin termination finish on this product series is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs TEMPERATURE DERATING GRAPHS Short Circuit types. All other types. W) 1 85°C W) 1 85°C er ( er ( w w o o P P ut Safe Operating Area ut Safe Operating Area p p ut ut 120°C O O 0 0 -40 0 50 100 150 -40 0 50 100 150 Ambient Temperature (°C) Ambient Temperature (°C) www.murata-ps.com/support KDC_NMR.F01 Page 3 of 10

NMR Series Isolated 1W Single Output DC/DC Converters EFFICIENCY VS LOAD NMR100C NMR101C NMR102 NMR106C NMR107C NMR108C www.murata-ps.com/support KDC_NMR.F01 Page 4 of 10

NMR Series Isolated 1W Single Output DC/DC Converters EFFICIENCY VS LOAD NMR118C NMR119C NMR120C NMR100PC 90 80 70 60 Efficiency (%)4500 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Load (%) www.murata-ps.com/support KDC_NMR.F01 Page 5 of 10

NMR Series Isolated 1W Single Output DC/DC Converters APPLICATION NOTES Minimum load The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%. Capacitive loading and start up Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF. Typical Start-Up Wave Form Start-up time Start-up time μs μs NMR100C 2301 NMR112C 744 NMR101C 5570 NMR113C 1908 NMR102C 8289 NMR114C 6620 NMR106C 783 NMR118C 671 NMR107C 4770 NMR119C 5335 NMR108C 4850 NMR120C 6370 NMR100PC 360 Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 1μF X7R m ultilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter 10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less C2 than 100mΩ at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450Ω resistor, carbon film, ±1% tolerance R2 50Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. Differential Mode Noise Test Schematic DC/DC Converter OSCILLOSCOPE C1 C2 C3 R1 T1 R2 + + Y INPUT SUPPLY Input Output - - R LOAD www.murata-ps.com/support KDC_NMR.F01 Page 6 of 10

NMR Series Isolated 1W Single Output DC/DC Converters APPLICATION NOTES (continued) Output Ripple Reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. Component selection Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended. The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter. Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be >20MHz. L DC Power C Load Source DC Inductor Capacitor L, μH SMD Through Hole C, μF NMR100C 10 82103C 11R103C 4.7 NMR101C 47 82473C 11R473C 1 NMR102C 47 82473C 11R473C 1 NMR106C 10 82103C 11R103C 4.7 NMR107C 47 82473C 11R473C 1 NMR108C 47 82473C 11R473C 1 NMR112C 10 82103C 11R103C 4.7 NMR113C 47 82473C 11R473C 1 NMR114C 47 82473C 11R473C 1 NMR118C 10 82103C 11R103C 4.7 NMR119C 47 82473C 11R473C 1 NMR120C 47 82473C 11R473C 1 NMR100PC 22 82223C 11R223C 1 www.murata-ps.com/support KDC_NMR.F01 Page 7 of 10

NMR Series Isolated 1W Single Output DC/DC Converters EMC FILTERING AND SPECTRA FILTERING The following filter circuit and filter table shows the input filters typically required to meet EN 55022 Curve B, Quasi-Peak EMC limit, as shown in the following plots. The following plots show positive and negative quasi peak and CISPR22 Average Limit B (pink line) and Quasi Peak Limit B (green line) adherence limits. L DC C DC C Ceramic capacitor Inductor Capacitor Part Number L, μH SMD Through Hole C, μF NMR100C NMR101C NMR102C NMR106C NMR107C NMR108C NMR118C NMR119C NMR120C NMR100PC 10 82103C 13R103C 10 NMR100C NMR101C NMR102C NMR106C www.murata-ps.com/support KDC_NMR.F01 Page 8 of 10

NMR Series Isolated 1W Single Output DC/DC Converters EMC FILTERING AND SPECTRA NMR107C NMR108C NMR118C NMR119C NMR120C NMR100PC 80 70 60 50 V Bu 40 d 30 20 10 0 1.00E+05 1.00E+06 1.00E+07 1.00E+08 Frequency (Hz) www.murata-ps.com/support KDC_NMR.F01 Page 9 of 10

NMR Series Isolated 1W Single Output DC/DC Converters PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS PIN CONNECTIONS - 7 PIN SIP 7 Pin SIP Package Pin Function 19.50±0.25 [0.768±0.010] 1 +VIN 2 -VIN 6.00±0.25 [0.236±0.010] 4 -VOUT 6 +VOUT TUBE OUTLINE DIMENSIONS 9.3 [0.366] 10.00±0.25 [0.394±0.010] S 4.10±0.5 [0.161±0.020] 0.50±0.05 [0.020±0.002] 5.08 [0.200] 0.25±0.05 [0.010±0.002] 12.43 [0.489] 18.0 [0.709] 1 2 4 6 (1.13 [0.044]) 2.54 [0.100] (1.93 [0.076]) 12.70 [0.500] 5.0 [0.197] Weight: 2.1g (C) 1.9g (PC) All dimensions in mm (inches) Controlling dimension is mm. Unless otherwise specified all dimensions in mm [inches] ±0.55mm [0.022]. Tube quantity: 35 All pins on a 2.54 (0.100) pitch and within ±0.1 (0.004) of true position from pin 1 at seating plane ‘S’ Tube Length : 520mm [20.472] ±2.0 [0.079]. RECOMMENDED FOOTPRINT DETAILS x4 HOLES 2.54 [0.100] Ø1.15 [Ø0.045] 1.00 0.039 2.54 [0.100] All dimensions in mm (inches) Controlling dimension is mm. This product is subject to the following operating requirements Murata Power Solutions, Inc. and the Life and Safety Critical Application Sales Policy: 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Refer to: http://www.murata-ps.com/requirements/ ISO 9001 and 14001 REGISTERED Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2016 Murata Power Solutions, Inc. www.murata-ps.com/support KDC_NMR.F01 Page 10 of 10

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: M urata: NMR100 NMR101 NMR102 NMR106 NMR107 NMR108 NMR108C NMR100C NMR102C NMR106C NMR101C NMR107C NMR120C NMR118C NMR119C NMR120 NMR112C NMR113C NMR114C