ICGOO在线商城 > 电路保护 > PTC 可复位保险丝 > LVR100S
数量阶梯 | 香港交货 | 国内含税 |
+xxxx | $xxxx | ¥xxxx |
查看当月历史价格
查看今年历史价格
LVR100S产品简介:
ICGOO电子元器件商城为您提供LVR100S由CORCOM/TYCO ELECTRONICS设计生产,在icgoo商城现货销售,并且可以通过原厂、代理商等渠道进行代购。 LVR100S价格参考。CORCOM/TYCO ELECTRONICSLVR100S封装/规格:PTC 可复位保险丝, 聚合物 PTC 自恢复保险丝 240V(265V Int) 1A Ih 通孔 径向,圆片式。您可以下载LVR100S参考资料、Datasheet数据手册功能说明书,资料中有LVR100S 详细功能的应用电路图电压和使用方法及教程。
参数 | 数值 |
产品目录 | |
描述 | POLYSWITCH PTC RESET 240V 1.00A可复位保险丝—PPTC 265V 10A 20AWG Lead |
产品分类 | |
品牌 | TE Connectivity / Raychem |
产品手册 | |
产品图片 | |
rohs | 符合RoHS无铅 / 符合限制有害物质指令(RoHS)规范要求 |
产品系列 | TE Connectivity / Raychem LVR100SPolySwitch LVR,Raychem |
mouser_ship_limit | 该产品可能需要其他文件才能进口到中国。 |
数据手册 | |
产品型号 | LVR100S |
R(最小/最大值) | 0.200 ~ 0.330 欧姆 |
产品培训模块 | http://www.digikey.cn/PTM/IndividualPTM.page?site=cn&lang=zhs&ptm=24704 |
产品目录绘图 | |
产品目录页面 | |
产品种类 | 可复位保险丝—PPTC |
保持电流 | 1 A |
其它名称 | RF0628-000 |
包装 | 散装 |
商标 | TE Connectivity / Raychem |
安装风格 | Through Hole |
封装 | Bulk |
封装/外壳 | 径向,圆盘 |
尺寸 | 24.4 mm L x 5.1 mm W x 5.1 mm H x 18.7 mm D |
工作温度范围 | - 40 C to + 85 C |
工厂包装数量 | 250 |
引线间隔 | 11.4 mm |
最大电压 | 240 VAC |
标准包装 | 250 |
特色产品 | http://www.digikey.cn/product-highlights/zh/polyswitch-lvr-devices/51051 |
电压-最大值 | 240V |
电流-保持(Ih)(最大值) | 1A |
电流-最大值 | 10A |
电流-跳闸(It) | 2A |
电阻 | 580 mOhms |
端接类型 | Radial |
类型 | PolySwitch Resettable Fuses |
系列 | LVR |
跳闸时间 | 21s |
跳闸电流 | 2 A |
零件号别名 | RF0628-000 |
额定电流—最大值 | 10 A |
PolySwitch® PRODUCT: LVR100S PTC Devices DOCUMENT: SCD26610 REV LETTER: J Overcurrent Protection Device REV DATE: JULY 26, 2016 PAGE NO.: 1 OF 3 Specification Status: Released Rated Operating Voltage at 20 °C (AC/DC): 240 V Maximum Interrupt Voltage / Current at 20 °C (AC/DC): 265 V, 10.0 A Insulating Material: Cured, Flame Retardant Modified Silicone (meeting UL94 V-0 requirements) Lead Material: 20 AWG Sn-Plated Copper (0.81mm/0.032” nominal diameter) Marking: TABLE I. DIMENSIONS: A B C D E MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX mm: -- 18.7 -- 24.4 8.9 11.4 5.1 -- -- 5.1 In*: -- (0.74) -- (0.96) (0.36) (0.45) (0.20) -- -- (0.20) *Rounded off approximation TABLE II. PERFORMANCE RATINGS @ 20 °C: HOLD TRIP RESISTANCE (Ω) TIME TO POST-TRIP TRIPPED-STATE CURRENT CURRENT TRIP(SEC) RESISTANCE (Ω) POWER DISSIPATION (A) (A) @ 5 A @ 240 V (W) R MIN R MAX MAX MAX TYP 1.0 2.0 0.218 0.334 21.0 0.580 2.87 Agency Recognitions: UL (File #E74889), CSA (File #78165), TUV, CQC Reference Documents: PS300, UL1434 Precedence: This specification takes precedence over documents referenced herein. Effectivity: Reference documents shall be the issue in effect on the date of invitation for bid. Caution: Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame. Materials Information ROHS Compliant ELV Compliant Pb-Free © 2016 Littelfuse,Inc. littelfuse.com Specifications are subject to change without notice. Revised July 26, 2016
PolySwitch® PRODUCT: LVR100S PTC Devices DOCUMENT: SCD26610 REV LETTER: J Overcurrent Protection Device REV DATE: JULY 26, 2016 PAGE NO.: 2 OF 3 Warning: Application Limitations for the LVR Product Line 1. Users should independently evaluate the suitability of and test each product selected for their own application. 2. This product should not be used in an application where the maximum interrupt voltage or maximum interrupt current can be exceeded in a fault condition. Operation beyond the maximum ratings or improper use may result in device damage and possible electrical arcing and flame. 3. A PPTC device is not a fuse - it is a nonlinear thermistor that limits current. Under a fault condition all PPTC devices go into a high resistance state but do not open circuit, so hazardous voltage may be present at PPTC locations. 4. The devices are intended for protection against occasional overcurrent or over temperature fault conditions and should not be used when repeated fault conditions or prolonged trip events are anticipated. 5. In most applications, power must be removed and the fault condition cleared in order to reset a PPTC device; however, under certain unusual conditions, a PPTC device may automatically reset. PPTC devices should not be used in an application where an automatic reset could create a safety hazard, such as garbage disposals and blenders. Appropriate qualification testing should be performed. 6. It is the responsibility of the user to determine the need for back up or fail safe protection to prevent damage that may occur in the event of abnormal function or failure of the PTC device. 7. Operation in circuits with a large inductance can generate a circuit voltage (Ldi/dt) above the rated voltage of a PPTC device. This product should not be used in an application where the maximum interrupt voltage or maximum interrupt current can be exceeded by inductive spikes. 8. Devices are not recommended for reflow soldering. 9. Device performance can be impacted negatively if devices are handled in a manner inconsistent with recommended electronic, thermal, or mechanical procedures for electronic components. 10. PTC devices are not recommended to be installed in applications where the device is constrained such that its PTC properties are inhibited, for example in rigid potting materials or in rigid housings, which lack adequate clearance to accommodate device expansion. 11. Contamination of the PTC material with certain silicone-based oils or some aggressive solvents can adversely impact the performance of the devices. © 2016 Littelfuse,Inc. littelfuse.com Specifications are subject to change without notice. Revised July 26, 2016
PolySwitch® PRODUCT: LVR100S PTC Devices DOCUMENT: SCD26610 REV LETTER: J Overcurrent Protection Device REV DATE: JULY 26, 2016 PAGE NO.: 3 OF 3 Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own applications. Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, military, aerospace, medical, lifesaving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. © 2016 Littelfuse,Inc. littelfuse.com Specifications are subject to change without notice. Revised July 26, 2016