图片仅供参考

详细数据请看参考数据手册

Datasheet下载
  • 型号: LVR055S
  • 制造商: CORCOM/TYCO ELECTRONICS
  • 库位|库存: xxxx|xxxx
  • 要求:
数量阶梯 香港交货 国内含税
+xxxx $xxxx ¥xxxx

查看当月历史价格

查看今年历史价格

产品参数

参数 数值
产品目录 电路保护电路保护
描述 POLYSWITCH PTC RESET 0.55A HOLD可复位保险丝—PPTC .55A 240VAC 20/5.5A Imax
产品分类 PTC 可复位保险丝可复位保险丝—PPTC
品牌 TE Connectivity / Raychem
产品手册 http://www.te.com/catalog/pn/en/758968-000
产品图片
rohs 符合RoHS无铅 / 符合限制有害物质指令(RoHS)规范要求
产品系列 TE Connectivity / Raychem LVR055SPolySwitch LVR,Raychem
mouser_ship_limit 该产品可能需要其他文件才能进口到中国。
数据手册 点击此处下载产品Datasheet
产品型号 LVR055S
R(最小/最大值) 0.450 ~ 0.730 欧姆
产品培训模块 http://www.digikey.cn/PTM/IndividualPTM.page?site=cn&lang=zhs&ptm=24704
产品目录绘图
产品目录页面 点击此处下载产品Datasheet
产品种类 可复位保险丝—PPTC
保持电流 0.55 A
其它名称 758968-000
包装 散装
商标 TE Connectivity / Raychem
安装风格 Through Hole
封装 Bulk
封装/外壳 径向
尺寸 14 mm L x 4.1 mm W x 21.7 mm H
工作温度范围 - 40 C to + 85 C
工厂包装数量 500
引线间隔 5.8 mm
最大电压 240 VAC
标准包装 500
特色产品 http://www.digikey.cn/product-highlights/zh/polyswitch-lvr-devices/51051
电压-最大值 240V
电流-保持(Ih)(最大值) 550mA
电流-最大值 7A
电流-跳闸(It) 1.25A
电阻 1.45 Ohms
端接类型 Radial
类型 PolySwitch Resettable Fuses
系列 LVR
跳闸时间 26s
跳闸电流 1.25 A
零件号别名 758968-000
额定电流—最大值 7 A

Datasheet

PDF Datasheet 数据手册内容提取

PolySwitch® PRODUCT: LVR055S PTC Devices DOCUMENT: SCD25565 REV LETTER: L Overcurrent Protection Device REV DATE: July 26, 2016 PAGE NO.: 1 OF 3 Specification Status: Released Rated Operating Voltage at 20 °C (AC/DC): 240 V Maximum Interrupt Voltage / Current at 20 °C (AC/DC): 265 V, 7.0 A 135 V, 20.0 A Insulating Material: Cured, Flame Retardant Epoxy Polymer Lead Material: S 20 AWG Sn-Plated Copper (0.81mm/0.032” nominal diameter) Marking: TABLE I. DIMENSIONS: A B C D E MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX mm: -- 14.0 -- 21.7 4.3 5.8 7.6 -- -- 4.1 in:* -- (0.55) -- (0.85) (0.17) (0.23) (030) -- -- (0.16) *Rounded off approximation TABLE II. PERFORMANCE RATINGS @ 20 °C: HOLD TRIP RESISTANCE TIME TO POST-TRIP TRIPPED-STATE CURRENT CURRENT (Ω) TRIP(SEC) RESISTANCE POWER DISSIPATION (A) (A) @ 2.75A (Ω) @ 265 V (W) R MIN R MAX MAX MAX TYP 0.55 1.25 0.45 0.73 26.0 1.45 3.4 *Post Trip Resistance measured after one hour. Agency Recognitions: UL (File #E74889), CSA (File #78165), TUV, CQC Reference Documents: PS300 Precedence: This specification takes precedence over documents referenced herein. Effectivity: Reference documents shall be the issue in effect on the date of invitation for bid. Warning: Refer to Page 2 of this document for application limitations Materials Information ROHS Compliant ELV Compliant Pb-Free © 2016 Littelfuse,Inc. littelfuse.com Specifications are subject to change without notice. Revised July 26, 2016

PolySwitch® PRODUCT: LVR055S PTC Devices DOCUMENT: SCD25565 REV LETTER: L Overcurrent Protection Device REV DATE: July 26, 2016 PAGE NO.: 2 OF 3 Warning: Application Limitations for the LVR Product Line 1. Users should independently evaluate the suitability of and test each product selected for their own application. 2. This product should not be used in an application where the maximum interrupt voltage or maximum interrupt current can be exceeded in a fault condition. Operation beyond the maximum ratings or improper use may result in device damage and possible electrical arcing and flame. 3. A PPTC device is not a fuse - it is a nonlinear thermistor that limits current. Under a fault condition all PPTC devices go into a high resistance state but do not open circuit, so hazardous voltage may be present at PPTC locations. 4. The devices are intended for protection against occasional overcurrent or over temperature fault conditions and should not be used when repeated fault conditions or prolonged trip events are anticipated. 5. In most applications, power must be removed and the fault condition cleared in order to reset a PPTC device; however, under certain unusual conditions, a PPTC device may automatically reset. PPTC devices should not be used in an application where an automatic reset could create a safety hazard, such as garbage disposals and blenders. Appropriate qualification testing should be performed. 6. It is the responsibility of the user to determine the need for back up or fail safe protection to prevent damage that may occur in the event of abnormal function or failure of the PTC device. 7. Operation in circuits with a large inductance can generate a circuit voltage (Ldi/dt) above the rated voltage of a PPTC device. This product should not be used in an application where the maximum interrupt voltage or maximum interrupt current can be exceeded by inductive spikes. 8. Devices are not recommended for reflow soldering. 9. Device performance can be impacted negatively if devices are handled in a manner inconsistent with recommended electronic, thermal, or mechanical procedures for electronic components. 10. PTC devices are not recommended to be installed in applications where the device is constrained such that its PTC properties are inhibited, for example in rigid potting materials or in rigid housings, which lack adequate clearance to accommodate device expansion. 11. Contamination of the PTC material with certain silicone-based oils or some aggressive solvents can adversely impact the performance of the devices. © 2016 Littelfuse,Inc. littelfuse.com Specifications are subject to change without notice. Revised July 26, 2016

PolySwitch® PRODUCT: LVR055S PTC Devices DOCUMENT: SCD25565 REV LETTER: L Overcurrent Protection Device REV DATE: July 26, 2016 PAGE NO.: 3 OF 3 Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own applications. Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, military, aerospace, medical, lifesaving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. © 2016 Littelfuse,Inc. littelfuse.com Specifications are subject to change without notice. Revised July 26, 2016