ICGOO在线商城 > L01Z050S05
数量阶梯 | 香港交货 | 国内含税 |
+xxxx | $xxxx | ¥xxxx |
查看当月历史价格
查看今年历史价格
L01Z050S05产品简介:
ICGOO电子元器件商城为您提供L01Z050S05由Tamura设计生产,在icgoo商城现货销售,并且可以通过原厂、代理商等渠道进行代购。 提供L01Z050S05价格参考以及TamuraL01Z050S05封装/规格参数等产品信息。 你可以下载L01Z050S05参考资料、Datasheet数据手册功能说明书, 资料中有L01Z050S05详细功能的应用电路图电压和使用方法及教程。
参数 | 数值 |
产品目录 | |
描述 | SENSOR CURRENT 50A 5V BI MOD板上安装电流传感器 50AT 4Vout Open Loop |
产品分类 | |
品牌 | Tamura |
产品手册 | |
产品图片 | |
rohs | 符合RoHS无铅 / 符合限制有害物质指令(RoHS)规范要求 |
产品系列 | 板上安装电流传感器,Tamura L01Z050S05- |
数据手册 | |
产品型号 | L01Z050S05 |
产品培训模块 | http://www.digikey.cn/PTM/IndividualPTM.page?site=cn&lang=zhs&ptm=24682 |
产品目录绘图 | |
产品目录页面 | |
产品种类 | 板上安装电流传感器 |
传感器/变换器类型 | Open Loop |
传感器类型 | 霍尔效应, 开环 |
其它名称 | MT7173 |
准确性 | - |
包装 | 散装 |
响应时间 | 10µs |
商标 | Tamura |
安装类型 | 通孔 |
封装/外壳 | 模块 |
工作温度 | -10°C ~ 80°C |
极化 | 双向 |
标准包装 | 50 |
灵敏度 | - |
用于测量 | AC/DC |
电压-电源 | 5V |
电流-检测 | 50A |
电流-电源(最大值) | 15mA |
电流额定值 | 50 A |
电源电压 | 5 V |
类型 | Current Sensor |
精度 | - |
线性度 | ±1% |
输出 | 比率, 电压 |
通道数 | 1 |
频率 | DC ~ 100kHz |
频率范围 | DC to 100 kHz |
CURRENT SENSORS L01Z 1/1 3 1307 Magnetic Proportion System / Through Type L01Z SERIES RoHS SPECIFICATIONS Ta=25℃, RL=10kΩ, Vcc=+5V Types L01Z050S05 L01Z100S05 L01Z150S05 L01Z200S05 L01Z300S05 L01Z400S05 L01Z500S05 L01Z600S05 Spec Primary norminal current If 50AT 100AT 150AT 200AT 300AT 400AT 500AT 600AT Saturation current If max If×1.25 Vref+1.5V±0.045V Rated output voltage Vo Vref+1.5V±0.035V(at If) (at If) Vo Saturation output voltage Vo min ≦0.5V, 4.5V ≦ Vo max min/max Offset voltage*1 Vof Vref±0.035V Vref±0.030V(at If = 0A) (at If = 0A) Output linearity( 0A〜If) εL ≦±1%( at If) Power supply voltage Vcc +5V±2% Consumption current Icc ≦ 15mA di/dt Response time tr ≦ 10µs( di/dt = 100A /µs) ≦±2mV / ℃ Thermal drift of gain TCVo (Without Tc Vof) ≦±1.5mV / ℃( Without Tc Vof) Thermal drift of offset TCVof ≦±2mV / ℃ ≦ ±1mV / ℃ Hysteresis error VOH ≦8mV(at If = 0A → If → 0A) ≦4mV(at If = 0A → If → 0A) ≦6mV(at If = 0A → If → 0A) Insulation voltage Vd AC2500V for 1 minute( Sensing current 0.5mA)inside of through hole ⇔ terminal Insulation resistance RIS ≧500MΩ( at DC500V)inside of through hole ⇔ terminal Ambient Operating temperature TA ー20℃~+80℃ Ambient storage temperature TS ー40℃~+85℃ *1 Vref=Vcc/2 DIMENSIONS (mm) Lot No. L01Z S05 38MAX 2.5 Terminal number 15 9 18.5MAX 2.5 1 Vout 7.5 2 12.8 2 GND 5. 3 +Vcc (+5V) Weight: X MA8 12 45g 275 5 3 Note 9. 0. 4 4 14.5 14.5 Unless otherwise specified, 2−φ1 123 tolerances shall be ±0.5mm 3−□0.65 Terminal number 82
CURRENT SENSORS Notices 1/1 3 1510 Important Notice 1. The content of this information is subject to change without 7. This product is not designed to resist radiation. prior notice for the purpose of improvements, etc. Ensure that ・ Use in liquids such as water, oil, chemical solutions, or you are in possession of the most up-to-date information when organic solvents, and use in locations where the product will using this product. be exposed to such liquids. ・ Use that involves exposure to direct sunlight, outdoor 2. This product is intended to be used in general electronics exposure, or dusty conditions. applications (electric home appliances, business equipment, ・ Use in locations where corrosive gases such as sea winds, information equipment, communication terminal equipment, Cl2, H2S, NH3, SO2, or NO2, are present. (Some product improves durability) measuring devices, industrial equipment, and so on). This ・ Use in environments with strong static electricity or product is neither intended nor warranted for use in following electromagnetic radiation. equipment or devices: ・ Use that involves placing inflammable material next to the Special application (such as for medical devices, product. transportation equipment, traffic signal control equipment, ・Use of this product either sealed with a resin filling or coated fire and crime prevention equipment, aeronautics and with resin. space devices, nuclear power control, fuel control, in- ・Use of water or a water soluble detergent for flux cleaning. vehicle equipment, safety devices, and so on) in which ・Use in locations where condensation is liable to occur. extremely high quality and high reliability is required, or if 8. Do not use or otherwise make available the TAMUTA the malfunction or failures of product could be cause loss of products or the technology described in this document for any human life, bodily injury. military purposes, including without limitation, for the design, Tamura Corporation shall not be held responsible for any development, use, stockpiling or manufacturing of mass damage incurred by customers or any third party when products destruction weapons (e.g. nuclear, chemical, or biological are used in special application, unless specifically permitted in weapons or missile technology products). When exporting this document. and re-exporting the products or technology described in this document, you should comply with the applicable export control 3. Tamura Corporation constantly strives to improve quality and laws and regulations and follow the procedures required by reliability, but malfunction or failures are bound to occur with such laws and regulations including, without limitation, Japan some probability in current sensor. To ensure that failures do -Foreign Exchange and Foreign Trade Control Law and U.S.- not cause accidents resulting in injury or death, fire accidents, Export Administration Regulations. The TAMURA products social damage, and so on, users are to thoroughly verify the and related technology should not be used for or incorporated safety of their designs in devices and/or systems. into any products or systems whose manufacture, use, or sale 4. The operation examples and circuit examples shown in this is prohibited under any applicable domestic or foreign laws or information are for reference purposes only, and Tamura regulations. Corporation disclaims all responsibility for any violations of 9. Please contact your TAMURA sales office for details as to industrial property rights, intellectual property rights and any environmental matters such as the RoHS compatibility of other rights owned by Tamura Corporation or third parties that Product. Please use TAMURA products in compliance with all these may entail. applicable laws and regulations that regulate the inclusion or 5. The circuit examples and part constants listed in these use of controlled substances, including without limitation, the specifications are provided as reference for the verification EU RoHS Directive. TAMURA assumes no liability for damages of characteristics. The user is to perform design, verification, or losses occurring as a result of your noncompliance with and judgment under his or her own responsibility, taking into applicable laws and regulations. account the various conditions. 10. T AMURA assumes no liability for damages or losses incurred by 6. The products are designed for use in environments where you or third parties as a result of unauthorized use of TAMURA consumer electronics are commonly used. It is not designed for products. use in special environments such as listed below, and if such 11. This document and any information herein may not be use is considered, the user is to perform thorough safety and reproduced in whole or in part without prior written permission reliability checks under his/her responsibility. from TAMURA. 9
CURRENT SENSORS Appli note 1/1 3 1709 Application notes <General Considerations> <Open loop> 1. The sensor uses polar electronic components. When the 1. High frequency primary current may result in excessive heating polarity of the power supply is mistaken, the sensor is damaged. in iron magnetic core and cause damage to internal circuitry; 2. Static electricity or excessive voltage can increase an offset for high frequency applications select current sensor with ferrite voltage in the Hall element, and cause offset voltage to change. core material. Please exercise care in handling and application. 2. If the measured current exceeds the rated current, magnetic 3. In order to prevent the influence of noise, the use of twisted core saturation will occur and the output voltage signal will not cable or shielded cable for the output line is recommended be linearly proportional to the measured current. 4. If using this device within a magnetic field generated by other devices, the specified accuracy may not be obtainable. <Closed Loop> 5. Our products( several models are excluded ) are adjusted 1. For closed loop current sensors please insure the power supply with the trimming method by the measurement condition voltage is balanced, symmetrical, and, applied simultaneously (Load resistance, Power supply voltage) of specification to avoid potential increase in DC offset error. sheets. Therefore, characteristics( Offset, Output, etc.) and its 2. Maximum rated current measurement duration is timedependent. deviation may be changed in different circuit conditions from Maximum rated current applied in excess of the time limit can the measurement condition. All change characteristic items are result in damage to internal electronic circuitry; please consult not indicated on specification sheets. Tamura for assistance. 6. The performance of current sensors with through-hole( aperture) 3. When using a measurement resistor to convert current output is dependent on the position of the primary conductor. Tamura to voltage output select a resistor with stable temperature specifications are based on a primary conductor completely characteristic to insure accuracy of the output voltage. filling the through-hole( aperture) area. 4. Compensation current supplied to the secondary winding varies 7. The current sensor rated current in DC Amps. in proportion to the measured current based on the conversion 8. Please use mating connector with equivalent terminal plating ratio.( If/KN; KN = secondary turns) Please insure the PSU material to insure proper operation and avoid possibility of has required current capacity to supply compensation current ‘galvanic corrosion’. to the secondary winding. 9. Please do not store in high-temperature and high-humidity storage environment. Please use it after confirming soldering <Flux-Gate> when it is kept for six months or more.( product soldered with substrate) 1. Compensation current supplied to the secondary winding varies 10. We recommend performing a zero offset adjustment by measuring in proportion to the measured current. Please insure the PSU the offset voltage at startup. In continuously operation for a few has required current capacity to supply compensation current months, or at change of ambient temperature or humidity is large, to the secondary winding. we recommend regularly performing a zero offset adjustment at 2. There is 450kHz ripple voltage present on the output and being idling( it is clear that the current is not apply). reference output voltage signals . An external capacitor maybe 11. The current sensor doesn't have built-in protection circuit added if necessary. (devices and fuses, etc.). As a failure mode of the sensor, there is a short circuit and open state. In the case of a short- circuit state, the abnor-mal temperature rise of the internal parts is assumed, and there is a possibility to smoke and to ignite. If it is used in safety critical circuit blocks, please take appropriate measures by protection devices, protection circuits, etc. For closed loop –type sensors and flux gate (closed loop type) sensors, the consumption current of the secondary power supply varies in proportion to the measurement current. 7