图片仅供参考

详细数据请看参考数据手册

Datasheet下载
  • 型号: HIH-4031-003
  • 制造商: Honeywell Solid State Electronics
  • 库位|库存: xxxx|xxxx
  • 要求:
数量阶梯 香港交货 国内含税
+xxxx $xxxx ¥xxxx

查看当月历史价格

查看今年历史价格

HIH-4031-003产品简介:

ICGOO电子元器件商城为您提供HIH-4031-003由Honeywell Solid State Electronics设计生产,在icgoo商城现货销售,并且可以通过原厂、代理商等渠道进行代购。 HIH-4031-003价格参考¥108.65-¥115.26。Honeywell Solid State ElectronicsHIH-4031-003封装/规格:湿度,湿敏传感器, Humidity Temperature Sensor 0 ~ 100% RH Analog Voltage ±3.5% RH 5s Surface Mount。您可以下载HIH-4031-003参考资料、Datasheet数据手册功能说明书,资料中有HIH-4031-003 详细功能的应用电路图电压和使用方法及教程。

产品参数 图文手册 常见问题
参数 数值
产品目录

传感器,变送器

描述

SENSOR HUMIDITY 5.8V 3.5% SMD板上安装湿度传感器 5.8V 3.5% SMD Humidity Sensor

产品分类

湿度传感器,湿度环境传感器

品牌

Honeywell Sensing and Control

产品手册

http://sensing.honeywell.com/honeywell-sensing-hih4030-4031%20series-product-sheet-009021-4-en.pdf?name=HIH-4031-001

产品图片

rohs

符合RoHS无铅 / 符合限制有害物质指令(RoHS)规范要求

产品系列

板上安装湿度传感器,Honeywell HIH-4031-003-

数据手册

http://sensing.honeywell.com/index.php/ci_id/51625/la_id/1/document/1/re_id/0http://sensing.honeywell.com/index.php/ci_id/49921/la_id/1/document/1/re_id/0

产品型号

HIH-4031-003

RH精度

3.5 %

RH范围

0 % to 100 %

产品

Board Mount

产品培训模块

http://www.digikey.cn/PTM/IndividualPTM.page?site=cn&lang=zhs&ptm=12218

产品目录页面

点击此处下载产品Datasheet

产品种类

板上安装湿度传感器

传感器类型

电容性

其它名称

480-3169
480-3169-1
480-3169-1-ND
HIH-4031-003S
HIH4031003

响应时间

5s

商标

Honeywell

商标名

HumidIcon

安装风格

SMD/SMT

封装

Reel

封装/箱体

8.59 mm X 4.17 mm X 2.67 mm

工作温度

-40°C ~ 85°C

工厂包装数量

1000

最大工作温度

+ 85 C

最小工作温度

- 40 C

标准包装

1,000

湿度范围

0 ~ 100% 相对湿度

灵敏度

-

电压-电源

4 V ~ 5.8 V

电容

-

电源电压-最大

5.8 V

电源电压-最小

4 V

电源电流

200 uA

精度

±3.5% RH

系列

HIH-4030/31

输出

线性电压

输出类型

Analog

推荐商品

型号:SI7023-A20-IM

品牌:Silicon Labs

产品名称:传感器,变送器

获取报价

型号:CC2D23

品牌:Amphenol Advanced Sensors

产品名称:传感器,变送器

获取报价

型号:SI7005-B-FM

品牌:Silicon Labs

产品名称:传感器,变送器

获取报价

型号:CC2D33-SIP

品牌:Amphenol Advanced Sensors

产品名称:传感器,变送器

获取报价

型号:SI7020-A10-IM

品牌:Silicon Labs

产品名称:传感器,变送器

获取报价

型号:SI7021-A10-GMR

品牌:Silicon Labs

产品名称:传感器,变送器

获取报价

型号:SI7021-A10-IM

品牌:Silicon Labs

产品名称:传感器,变送器

获取报价

型号:SI7005-B-FM1

品牌:Silicon Labs

产品名称:传感器,变送器

获取报价

样品试用

万种样品免费试用

去申请
HIH-4031-003 相关产品

HTS221TR

品牌:STMicroelectronics

价格:

SI7020-A10-IM1

品牌:Silicon Labs

价格:

SI7021-A20-GM1

品牌:Silicon Labs

价格:

CC2D33-SIP

品牌:Amphenol Advanced Sensors

价格:¥56.77-¥60.22

HIH-4030-003

品牌:Honeywell Sensing and Productivity Solutions

价格:¥136.32-¥158.91

SI7005-B-GM1

品牌:Silicon Labs

价格:

HIH-5031-001

品牌:Honeywell Sensing and Productivity Solutions

价格:

SI7020-A20-IM1

品牌:Silicon Labs

价格:

PDF Datasheet 数据手册内容提取

HIH-4030/31 Series Humidity Sensors DESCRIPTION The HIH-4030/4031 Series delivers instrumentation-quality RH Honeywell has expanded our HIH Series to include an SMD (Relative Humidity) sensing performance in a competitively (Surface Mount Device) product line: the new HIH 4030/4031. priced, solderable SMD. The HIH 4030/4031 complements our existing line of non-SMD humidity sensors. SMD packaging on tape and reel allows for The HIH-4030 is a covered integrated circuit humidity sensor. use in high volume, automated pick and place manufacturing, The HIH-4031 is a covered, condensation-resistant, integrated eliminating lead misalignment to printed circuit board through- circuit humidity sensor that is factory-fitted with a hydrophobic hole. filter allowing it to be used in condensing environments including industrial, medical and commercial applications. The HIH-4030/4031 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment The RH sensor uses a laser trimmed, thermoset polymer Manufacturer) users. capacitive sensing element with on-chip integrated signal conditioning. Direct input to a controller or other device is made possible by this sensor’s near linear voltage output. With a typical current The sensing element's multilayer construction provides draw of only 200 μA, the HIH-4030/4031 Series is often ideally excellent resistance to most application hazards such as suited for low drain, battery operated systems. condensation, dust, dirt, oils and common environmental chemicals. Tight sensor interchangeability reduces or eliminates OEM production calibration costs. Individual sensor calibration data Sample packs are available. See order guide. is available. FEATURES POTENTIAL APPLICATIONS • Tape and reel packaging allows for use in high volume pick • Refrigeration equipment and place manufacturing (1,000 units per tape and reel) • HVAC (Heating, Ventilation and Air Conditioning) • Molded thermoset plastic housing equipment • Near linear voltage output vs %RH • Medical equipment • Laser trimmed interchangeability • Drying • Low power design • Metrology • Enhanced accuracy • Battery-powered systems • Fast response time • OEM assemblies • Stable, low drift performance • Chemically resistant

HIH-4030/31 Series TABLE 1. PERFORMANCE SPECIFICATIONS (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.) Parameter Minimum Typical Maximum Unit Specific Note Interchangeability (first order curve) – – – – – 0% RH to 59% RH -5 – 5 % RH – 60% RH to 100% RH -8 – 8 % RH – Accuracy (best fit straight line) -3.5 – +3.5 % RH 1 Hysterisis – 3 – % RH – Repeatability – ±0.5 – % RH – Settling time – – 70 ms – Response time (1/e in slow moving air) – 5 – s – Stability (at 50% RH in a year) – ±1.2 – % RH 2 Stability (at 50% RH in a year) – ±0.5 – % RH 3 Voltage supply 4 – 5.8 Vdc 4 Current supply – 200 500 μA – Voltage output (1st order curve fit) V =(V )(0.0062(sensor RH) + 0.16), typical at 25 ºC OUT SUPPLY Temperature compensation True RH = (Sensor RH)/(1.0546 – 0.00216T), T in ºC Output voltage temp. coefficient at 50% RH, 5 V – -4 – mV/ºC – Operating temperature -40[-40] See Figure 1. 85[185] ºC[ºF] – Operating humidity (HIH-4030) 0 See Figure 1. 100 % RH 5 Operating humidity (HIH-4031) 0 See Figure 1. 100 % RH – Storage temperature -50[-58] – 125[257] ºC[ºF] – Storage humidity See Figure 2. % RH 5 Specific Notes: General Notes: 1. Can only be achieved with the supplied slope and offset. For • Sensor is ratiometric to supply voltage. HIH-4030/31-003 catalog listings only. • Extended exposure to >90% RH causes a reversible 2. Includes testing outside of recommended operating zone. shift of 3% RH. 3. Includes testing for recommended operating zone only. • Sensor is light sensitive. For best performance, shield 4. Device is calibrated at 5 Vdc and 25 ºC. sensor from bright light. 5. Non-condensing environment. When liquid water falls on the humidity sensor die, output goes to a low rail condition indicating no humidity. FACTORY CALIBRATION DATA HIH-4030/31 Sensors may be ordered with a calibration and data printout. See Table 2 and the order guide on the back page. TABLE 2. EXAMPLE DATA PRINTOUT Model HIH-4030-003 Channel 92 Wafer 030996M MRP 337313 Calculated values at 5 V V at 0% RH 0.958 V OUT V at 75.3% RH 3.268 V OUT Linear output for 3.5% RH accuracy at 25 °C Zero offset 0.958 V Slope 30.680 mV/%RH Sensor RH (V - zero offset)/slope OUT (V - 0.958)/0.0307 OUT Ratiometric response for 0% RH to 100% RH V V (0.1915 to 0.8130) OUT SUPPLY 2 www.honeywell.com/sensing

Humidity Sensors FIGURE 1. OPERATING ENVIRONMENT (Non-condensing environment for HIH-4030 catalog listings only.) FIGURE 2. STORAGE ENVIRONMENT (Non-condensing environment for HIH-4030 catalog listings only.) 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% -40 -20 0 20 40 60 80 100 120 140 Recommended storage zone Temperature ºC Honeywell Sensing and Control 3

HIH-4030/31 Series FIGURE 3. TYPICAL OUTPUT VOLTAGE VS RELATIVE HUMIDITY (At 25 ºC and 5 V.) 4 3.5 3 c) d V ge ( 2.5 Sensor Response a olt Sensor Response V ut 2 Best Linear Fit p ut O 1.5 1 0.5 0 20 40 60 80 100 Relative Humidity (%RH) FIGURE 4. TYPICAL OUTPUT VOLTAGE (BFSL) VS RELATIVE HUMIDITY (At 0 ºC, 70 ºC and 5 V.) 4.5 4 3.5 3 c) d V e ( 2.5 ag 0 C olt 70 C V ut 2 p ut O 1.5 1 0.5 0 0 10 20 30 40 50 60 70 80 90 100 Relative Humidity (%) 4 www.honeywell.com/sensing

Humidity Sensors FIGURE 5. HIH-4030 MOUNTING DIMENSIONS (For reference only. mm/[in]) Honeywell Sensing and Control 5

HIH-4030/31 Series FIGURE 6. HIH-4031 MOUNTING DIMENSIONS (For reference only. mm/[in]) FIGURE 7. HIH-4031 PCB LANDING PATTERN (For reference only. mm/[in]) 6 www.honeywell.com/sensing

Humidity Sensors FIGURE 8. TAPE AND REEL DIMENSIONS (For reference only. mm/[in]) 3,99 [0.157] DIA. 1,50 1,75 3,91 2,01 [0.059] [0.069] [0.154] [0.079] 2,64 [0.104] 11,51 [0.453] 24,00 2,64 [0.945] [0.076] 22,25 [0.876] DIA. 1,50 [0.059] 8,00 [0.315] 0,343 [0.0135] FIGURE 9. TYPICAL APPLICATION CIRCUIT ORDER GUIDE Catalog Listing Description HIH-4030-001 Covered integrated circuit humidity sensor, SMD, 1000 units on tape and reel HIH-4030-003 Covered integrated circuit humidity sensor, SMD, calibration and data printout, 1000 units on tape and reel HIH-4031-001 Covered, filtered integrated circuit humidity sensor, SMD, 1000 units on tape and reel HIH-4031-003 Covered, filtered integrated circuit humidity sensor, SMD, calibration and data printout, 1000 units on tape and reel HIH-4030-001S Sample pack: covered integrated circuit humidity sensor, SMD, five units on tape HIH-4030-003S Sample pack: covered integrated circuit humidity sensor, SMD, calibration and data printout, five units on tape HIH-4031-001S Sample pack: covered, filtered integrated circuit humidity sensor, SMD, sample pack, five units on tape HIH-4031-003S Sample pack: covered, filtered integrated circuit humidity sensor, SMD, calibration and data printout, five units on tape FURTHER HUMIDITY SENSOR INFORMATION See the following associated literature is available on the Web: • Product installation instructions • Application sheets: – Humidity Sensor Performance Characteristics – Humidity Sensor Theory and Behavior – Humidity Sensor Moisture and Psychrometrics – Thermoset Polymer-based Capacitive Sensors Honeywell Sensing and Control 7

WARNING WARNING MISUSE OF DOCUMENTATION PERSONAL INJURY • The information presented in this product sheet is for DO NOT USE these products as safety or emergency stop reference only. Do not use this document as a product devices or in any other application where failure of the installation guide. product could result in personal injury. • Complete installation, operation, and maintenance Failure to comply with these instructions could result information is provided in the instructions supplied with in death or serious injury. each product. Failure to comply with these instructions could result SALES AND SERVICE in death or serious injury. Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For WARRANTY/REMEDY application assistance, current specifications, pricing or name Honeywell warrants goods of its manufacture as being free of of the nearest Authorized Distributor, contact your local sales defective materials and faulty workmanship. Honeywell’s office or: standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order E-mail: info.sc@honeywell.com acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell Internet: www.honeywell.com/sensing during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The Phone and Fax: foregoing is buyer’s sole remedy and is in lieu of all other Asia Pacific +65 6355-2828 warranties, expressed or implied, including those of +65 6445-3033 Fax merchantability and fitness for a particular purpose. In no Europe +44 (0) 1698 481481 event shall Honeywell be liable for consequential, special, +44 (0) 1698 481676 Fax or indirect damages. Latin America +1-305-805-8188 +1-305-883-8257 Fax While we provide application assistance personally, through USA/Canada +1-800-537-6945 our literature and the Honeywell web site, it is up to the +1-815-235-6847 customer to determine the suitability of the product in the +1-815-235-6545 Fax application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sensing and Control Honeywell 1985 Douglas Drive North Minneapolis, MN 55422 009021-4-EN IL50 GLO Printed in USA March 2008 www.honeywell.com/sensing © 2008 Honeywell International Inc. All rights reserved.