ASDXRRX015PDAA5产品简介:
ICGOO电子元器件商城为您提供ASDXRRX015PDAA5由Honeywell Solid State Electronics设计生产,在icgoo商城现货销售,并且可以通过原厂、代理商等渠道进行代购。 ASDXRRX015PDAA5价格参考¥234.22-¥234.22。Honeywell Solid State ElectronicsASDXRRX015PDAA5封装/规格:压力传感器,变送器, 差分 压力 传感器 ±15 PSI(±103.42 kPa) 公型 - 0.09"(2.31mm) 双管 0.5 V ~ 4.5 V 8-DIP 模块。您可以下载ASDXRRX015PDAA5参考资料、Datasheet数据手册功能说明书,资料中有ASDXRRX015PDAA5 详细功能的应用电路图电压和使用方法及教程。
参数 | 数值 |
产品目录 | |
描述 | SENSOR PRESS 15PSID ANALOG板机接口压力传感器 15psi 5V Analog Output |
产品分类 | |
品牌 | Honeywell |
产品手册 | http://sensing.honeywell.com/index.php?ci_id=45333 |
产品图片 | |
rohs | 符合RoHS无铅 / 符合限制有害物质指令(RoHS)规范要求 |
产品系列 | 板机接口压力传感器,Honeywell ASDXRRX015PDAA5ASDX |
数据手册 | http://sensing.honeywell.com/index.php/ci_id/45330/la_id/1/document/1/re_id/0http://sensing.honeywell.com/index.php/ci_id/45325/la_id/1/document/1/re_id/0 |
产品型号 | ASDXRRX015PDAA5 |
产品种类 | 板机接口压力传感器 |
其它名称 | 480-4489 |
准确性 | 2 % |
出厂设置 | - |
压力类型 | Differential |
商标 | Honeywell |
安装风格 | Through Hole |
封装 | Bulk |
封装/外壳 | 8-DIP 模块 |
封装/箱体 | DIP |
工作压力 | +/- 15 psi |
工作温度 | -20°C ~ 105°C |
工作电源电压 | 5 V |
最大工作温度 | + 105 C |
最小工作温度 | - 20 C |
标准包装 | 1 |
电压-电源 | 4.75 V ~ 5.25 V |
电源电压-最大 | 6 V |
电源电压-最小 | 3 V |
端口大小 | 2.31 mm |
端口尺寸 | 公型,0.091"(2.31mm)双管 |
端口类型 | Dual Radial Barbless |
端子类型 | PCB |
精度 | ±2% |
系列 | ASDX |
输出 | 模拟 |
输出类型 | Analog |
ASDX Series Silicon Pressure Sensors DESCRIPTION The ASDX Series is a Silicon Pressure Sensor offering either These sensors are available to measure absolute, differential an I2C or SPI digital interface for reading pressure over the and gage pressures. The absolute versions have an internal specified full scale pressure span and temperature range. vacuum reference and an output value proportional to absolute pressure. Differential versions allow application of pressure to The ASDX is fully calibrated and temperature compensated for either side of the sensing diaphragm. Gage versions are sensor offset, sensitivity, temperature effects and non-linearity referenced to atmospheric pressure and provide an output using an on-board Application Specific Integrated Circuit proportional to pressure variations from atmosphere. (ASIC). Calibrated output values for pressure are updated at approximately 1 kHz. The ASDX Series sensors are intended for use with non- corrosive, non-ionic working fluids such as air and dry gases. The standard ASDX is calibrated over the temperature range They are designed and manufactured according to standards of 0 °C to 85 °C [32 °F to 185 °F]. The sensor is characterized in ISO 9001. for operation from a single power supply of either 3.3 Vdc or 5.0 Vdc. FEATURES POTENTIAL APPLICATIONS Output options: I2C- or SPI-compatible 12-bit digital Flow calibrators Precision ASIC conditioning and temperature Ventilation and air flow monitors compensated over 0 °C to 85 °C [32 °F to 185 °F] Gas flow instrumentation temperature range Sleep apnea monitoring and therapy equipment Low operating voltage Barometry Absolute, differential and gage types Pneumatic controls Pressure ranges from 10 inches H2O to 100 psi HVAC Standard calibrations in inches H2O, cm H20, psi, mbar, bar, kPa Total error band of ±2.0% of full scale span maximum RoHS compliant
ASDX Series Silicon Pressure Sensors Table 1. Absolute Maximum Ratings1 Parameter Min Max Unit Supply voltage (Vsupply) -0.3 6.0 Vdc Voltage to any pin -0.3 Vsupply + 0.3 Vdc Digital clock frequency: I2C 100 400 kHz SPI 50 800 ESD susceptibility (human body model) 3 - kV Storage temperature -50 [-58] 125 [257] °C [°F] Lead temperature (2 s to 4 s) - 250 [482] °C [°F] External capacitance between Vsupply and ground2 100 470 nF Table 2. Operating Specifications Parameter Min. Typ. Max. Unit Supply voltage: (Vsupply)3 3.3 Vdc 3.0 3.34 3.6 5.0 Vdc 4.75 5.04 5.25 Vdc Sensors are either 3.3 Vdc or 5.0 Vdc per the Order Guide (see Figure 1). Supply current 2.0 3.5 5.0 mA Compensated temperature range5 0 [32] - 85 [185] °C [°F] Operating temperature range6 -20 [-4] - 105 [221] °C [°F] Overpressure7 2X operating pressure range minimum Burst pressure8 3X operating pressure range minimum Startup time (power up to data ready) - 2.8 7.3 ms Response time - 0.46 - ms I2C or SPI voltage level low - - 0.2 Vsupply I2C or SPI voltage level high 0.8 - - Vsupply Pull-up on SDA and SCL (I2C output only) 1 - - kOhm Total error band9 - - 2.0 %FSS10 Output resolution 12 - - bits Table 3. Environmental Specifications Parameter Characteristic Humidity 0% to 95% RH non-condensing Vibration 10 G at 20 Hz to 2000 Hz Shock 100 G for 11 ms Life 1 million cycles minimum Table 4. Wetted Materials11 Parameter Port 1 (Pressure Port)12 Port 2 (Reference Port)12 Covers glass-filled PBT glass-filled PBT Adhesives silicone silicone and epoxy Electronic components silicon and glass silicon, glass, and gold Notes: 1. Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. 2. An external bypass capacitor is required across the supply voltage (Pins 6 and 3 – see Figure 4) as close to the sensor supply pin as possible for correct sensor operation. 3. Ratiometricity of the sensor (the ability of the output to scale to the input voltage) is achieved within the specified operating voltage for each option. Other custom supply voltages are available, please contact Honeywell Customer Service. 4. The sensor is not reverse polarity protected. Incorrect application of excitation voltage or ground to the wrong pin may cause electrical failure. 5. The compensated temperature range is the temperature range (or ranges) over which the sensor will produce an output proportional to pressure within the specified performance limits. 6. The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not remain within the specified performance limits. 7. Overpressure is the maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. 8. Burst pressure is the maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond the burst pressure. 9. Total error band is the maximum deviation in output from ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span and thermal hysteresis. Specification units are in percent of full scale span (%FSS). 10. Full scale span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of the pressure range. 11. Consult Honeywell Customer Service for detailed material information. 12. For AC pressure port configuration, the “pressure” and “reference” ports are reversed. 2 sensing.honeywell.com
Figure 1. Nomenclature and Order Guide Package Selection13 Calibration Selection ASDX _ _ X _ _ _ _ _ _ _ _ Series Power Supply Voltage 3 = 3.3 Vdc 5 = 5.0 Vdc Pressure Port Transfer Function Limits14 AV = Axial port on top, vented cover on bottom A = 10% to 90% calibration B = 5% to 95% calibration Output Type15 S = SPI 2 = I2C, Address 0x28 3 = I2C, Address 0x38 4 = I2C, Address 0x48 5 = I2C, Address 0x58 RR = Radial port on top, radial port on bottom 6 = I2C, Address 0x68 7 = I2C, Address 0x78 Pressure Range16, 17, 18 Gage Differential Absolute - 005ND = ±5 in H2O - 010NG = 10 in H2O 010ND = ±10 in H2O - AC = Axial port, sealed cover (commonly used for absolute) - 015CD = ±15 cm H2O - 025CG = 25 cm H2O 025CD = ±25 cm H2O - 001PG = 1 psi 001PD = ±1 psi - 005PG = 5 psi 005PD = ±5 psi - 015PG = 15 psi 015PD = ±15 psi 015PA = 15 psi 030PG = 30 psi 030PD = ±30 psi 030PA = 30 psi 100PG = 100 psi - 100PA = 100 psi - 015MD = ±15 mbar - RV = Radial port, single 025MG = 25 mbar 025MD = ±25 mbar - 050MG = 50 mbar 050MD = ±50 mbar - 100MG = 100 mbar 100MD = ±100 mbar - 200MG = 200 mbar 200MD = ±200 mbar - 500MG = 500 mbar 500MD = ±500 mbar - 001BG = 1 bar 001BD = ±1 bar 001BA = 1 bar 002BG = 2 bar 002BD = ±2 bar 002BA = 2 bar 007BG = 7 bar - 007BA = 7 bar 003KG = 3 kPa 003KD = ±3 kPa - 004KG = 4 kPa 004KD = ±4 kPa - Future Option 005KG = 5 kPa 005KD = ±5 kPa - 010KG = 10 kPa 010KD = ±10 kPa - 020KG = 20 kPa 020KD = ±20 kPa - 050KG = 50 kPa 050KD = ±50 kPa - 100KG = 100 kPa 100KD = ±100 kPa 100KA = 100 kPa 200KG = 200 kPa 200KD = ±200 kPa 200KA = 200 kPa 700KG = 700 kPa - 700KA = 700 kPa Notes: 13. Other package combinations are possible, please contact Honeywell Customer Service. 14. The transfer function limits define the output of the sensor at a given pressure input. By specifying the output signal at the maximum (Pmax.) and minimum (Pmin.) limits of the pressure range, the complete transfer curve for the sensor is defined. See Figure 2 for a graphical representation of each calibration. For the 12-bit digital output, Table 6 provides the output of the sensor at significant percentages. These outputs are valid at the rated input voltage of the sensor. 15. The output type defines which communication protocol the sensor uses to communicate. Available protocols are I2C or half duplex SPI (sensor acts only as a slave). This communication protocol is not field selectable, and must be defined when ordering the sensor. 16. Custom pressure ranges are available, please contact Honeywell Customer Service. 17. The pressure units (inches H2O, cm H2O, psi, mbar, bar, kPa) define the units used during calibration and in the application. 18. See Table 5 for an explanation of sensor types. Honeywell Sensing and Control 3
ASDX Series Silicon Pressure Sensors Table 5. Sensor Types Type Description Absolute Output is proportional to difference between applied pressure and built-in reference to vacuum (zero pressure). Gage Output is proportional to difference between applied pressure and atmospheric (ambient) pressure. Differential Output is proportional to difference between pressure applied to each of the pressure ports (Port 1 – Port 2). Figure 2. Transfer Functions and Limits A Calibration, 10% to 90% B Calibration, 5% to 95% Table 6. Sensor Output at Significant Percentages % Output Digital Counts (dec) Digital Counts (hex) 0% 0 0x0000 5% 819 0x0333 10% 1638 0x0666 50% 8192 0x2000 90% 14746 0x399A 95% 15565 0x3CCD 100% 16383 0x3FFF Figure 3. Completed Catalog Listing Example ASDXAVX001PG2A3: ASDXAVX001PG2A3 Output vs Pressure AV pressure port, 1 psi gage, I2C output (Address 0x28), 10% to 90% calibration at 3.3 Vdc operation. 4 sensing.honeywell.com
Figure 4. Dimensional Drawings (For reference only: mm [in].) AV Package (Legacy G2) RR Package (Legacy D4) AC Package (Legacy A2) RV Package Table 7. Pinout I2C SPI Pin Definition Type Description Pin Definition Type Description 1 SDA digital I/O serial bidirectional data; 1 MISO digital output “Master In Slave Out” - serial data is clocked in or out on output data; data is clocked clock edge of SCL out on clock edge of SCK 2 SCL digital input serial clock input; used to 2 SCK digital input serial clock input; used to clock data on SDA clock data on MISO 3 GND supply power supply ground 3 GND supply power supply ground 4 N/C not used do not connect in the 4 N/C not used do not connect in the application application 5 SS digital output interrupt signal (conversion 5 SS digital input slave select complete output) 6 Vsupply supply power supply source 6 Vsupply supply power supply source 7 N/C not used do not connect in the 7 N/C not used do not connect in the application application 8 N/C not used do not connect in the 8 N/C not used do not connect in the application application Honeywell Sensing and Control 5
WARNING WARNING PERSONAL INJURY MISUSE OF DOCUMENTATION DO NOT USE these products as safety or emergency stop The information presented in this product sheet is for devices or in any other application where failure of the reference only. Do not use this document as a product product could result in personal injury. installation guide. Failure to comply with these instructions could result Complete installation, operation, and maintenance in death or serious injury. information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in WARRANTY/REMEDY death or serious injury. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise SALES AND SERVICE by Honeywell in writing; please refer to your order Honeywell serves its customers through a worldwide network acknowledgement or consult your local sales office for specific of sales offices, representatives and distributors. For warranty details. If warranted goods are returned to Honeywell application assistance, current specifications, pricing or name during the period of coverage, Honeywell will repair or replace, of the nearest Authorized Distributor, contact your local sales at its option, without charge those items it finds defective. The office or: foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of E-mail: info.sc@honeywell.com merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, Internet: sensing.honeywell.com or indirect damages. Phone and Fax: While we provide application assistance personally, through Asia Pacific +65 6355-2828; +65 6445-3033 Fax our literature and the Honeywell web site, it is up to the Europe +44 (0) 1698 481481; +44 (0) 1698 481676 Fax customer to determine the suitability of the product in the Latin America +1-305-805-8188; +1-305-883-8257 Fax application. USA/Canada +1-800-537-6945; +1-815-235-6847 +1-815-235-6545 Fax Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 008095-13-EN July 2014 sensing.honeywell.com Copyright © 2014 Honeywell International Inc. All rights reserved.
Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: H oneywell: ASDX001D44D-DO ASDX001D44R-DO ASDX001G24R-DO ASDX005D44D-DO ASDX005D44R ASDX005D44R- DO ASDX005G24R-DO ASDX015A24R-DO ASDX015D44D-DO ASDX015D44R ASDX015D44R-DO ASDX015G24R-DO ASDX030A24R ASDX030A24R-DO ASDX030D44D ASDX030D44D-DO ASDX030D44R ASDX030D44R-DO ASDX030G24R-DO ASDX100A24R ASDX100A24R-DO ASDX100D44D ASDX100D44R ASDX100D44R-DO ASDX100G24R ASDX100G24R-DO ASDXACX030PA7A5 ASDXACX030PAAA5 ASDXAVX001PG7A5 ASDXRRX005PD7A5 ASDXRRX015PDAA5 ASDXRRX015PG7A5 ASDXRRX030PG7A5 ASDXRRX030PGAA5 ASDXRRX100PG7A5 ASDXRRX100PGAA5 ASDXAVX005PG7A5 ASDXRRX001PD7A5 ASDXRRX001PG7A5 ASDXRRX005PG7A5 ASDX100D44D-DO ASDXL10D44D ASDXL10D44D-DO ASDXL10D44R ASDXRRX001PG2A5 ASDXAVX001PG2A5 ASDXRRX001PD2A5 ASDXRRX005PG2A5 ASDXAVX005PG2A5 ASDXRRX005PD2A5 ASDXRRX001PGAA5 ASDXAVX001PGAA5 ASDXRRX001PDAA5 ASDXRRX005PGAA5 ASDXAVX005PGAA5 ASDXRRX005PDAA5 ASDXAVX010NG2A5 ASDXAVX010NG7A5 ASDXAVX010NGAA5 ASDXRRX005ND2A5 ASDXRRX005ND7A5 ASDXRRX005NDAA5 ASDXRRX010ND2A5 ASDXRRX010ND7A5 ASDXRRX010NDAA5 ASDXRRX010NG2A5 ASDXRRX010NG7A5 ASDXRRX010NGAA5 ASDXACX015PAAA5 ASDXACX015PASA5 ASDXACX015PA7A5 ASDXRRX030PDAA5 ASDXAVX030PG7A5 ASDXAVX100PGAA5 ASDXAVX100PG7A5 ASDXACX030PA2A5 ASDXACX100PA2A5 ASDXACX100PA7A5 ASDXACX100PAAA5 ASDXAVX015PG7A5 ASDXAVX015PGAA5 ASDXAVX030PG2A5 ASDXAVX030PGAA5 ASDXAVX100PG2A5 ASDXRRX015PD2A5 ASDXRRX015PD7A5 ASDXRRX015PG2A5 ASDXRRX015PGAA5 ASDXRRX030PG2A5 ASDXRRX100PD7A5 ASDXRRX100PG2A5 ASDXACX015PA2A5 ASDXACX015PA7A3 ASDXACX015PA2A3 ASDXRRX010ND7A3 ASDX005D44D ASDX015G24R ASDX001D44R ASDX001G24R ASDX015A24R