ICGOO在线商城 > 960
数量阶梯 | 香港交货 | 国内含税 |
+xxxx | $xxxx | ¥xxxx |
查看当月历史价格
查看今年历史价格
960产品简介:
ICGOO电子元器件商城为您提供960由3M设计生产,在icgoo商城现货销售,并且可以通过原厂、代理商等渠道进行代购。 提供960价格参考以及3M960封装/规格参数等产品信息。 你可以下载960参考资料、Datasheet数据手册功能说明书, 资料中有960详细功能的应用电路图电压和使用方法及教程。
参数 | 数值 |
产品目录 | |
描述 | AIR IONIZER MINI BLOWER防静电控制产品 MINI AIR IONIZER |
产品分类 | |
品牌 | 3M |
产品手册 | |
产品图片 | |
rohs | 否不适用 / 不适用 |
产品系列 | 3M Electronic Specialty 960960 |
mouser_ship_limit | 由于产品尺寸或重量的缘故,您的运费可能增加。 |
数据手册 | http://multimedia.3m.com/mws/mediawebserver?6666660Zjcf6lVs6EVs666bwPCOrrrrQ-http://multimedia.3m.com/mws/mediawebserver?66666UuZjcFSLXTt4XTVNx&XEVuQEcuZgVs6EVs6E666666-- |
产品型号 | 960 |
产品 | Air Ionizers |
产品种类 | 防静电控制产品 |
其它名称 | 0-00-51138-74678-0 |
单位重量 | 5.443 kg |
商标 | 3M Electronic Specialty |
大小 | 4.5 in x 3.3 in x 2 in |
安装类型 | 台式,便携式 |
工厂包装数量 | 12 |
描述/功能 | Generates ionized air particles which neutralizes any stray electrostatic buildup on surfaces |
标准包装 | 1 |
特色产品 | http://www.digikey.cn/product-highlights/zh/3m-static-control/52176http://www.digikey.cn/product-highlights/zh/3m-air-ionizers/52895 |
电压-输入 | 24VAC |
电缆类型 | Cord Type US |
相关产品 | /product-detail/zh/960X%2F980X/SCP286-ND/1239405 |
类型 | 电离器 |
系列 | 960 |
零件号别名 | 05113874678 98079843748 |
USER GUIDE TB-9008 Mini Air Ionizer Installation, Operation and Maintenance The Mini Air Ionizer requires 24 VAC power supplied through a RJ-11 power socket located on the back of the unit. It is possible to connect four (4) Mini Air Ionizers together in series and power them off of one power supply. Use the included RJ-11 cable to daisy-chain the Mini Air Ionizer to another Mini Air Ionizer. A third or fourth Mini Air Ionizer can be daisy-chained using additional RJ-11 cables. To reduce the risk of electric shock, the power supplies use a grounding plug that has a third (grounding) pin. This plug will only fit into a grounding-type power outlet. If the plug does not fit into the outlet, contact qualified personnel to install the proper outlet. Do not alter the plug in any way. If an alternate power source is used, please make sure that it conforms to the power input requirements as listed in the Specifications section. For further questions concerning the power-input requirements, please contact SCS Customer Service. Packaging Figure 1. SCS 960 Mini Air Ionizer 1 Mini Air Ionizer Description 1 RJ-11 Cable, 3 ft. 1 Certificate of Calibration The SCS Mini Air Ionizer is a self-contained ionizing air blower designed to neutralize static charges from NOTE: Power adapter is not included and must be non-conductive objects. The proprietary circuitry purchased separately. contained in the blower generates balanced levels of positive and negative ions, and maintains correct Installation balance despite variations in line voltage, fan speed, and emitter point condition. Meets ANS/ESD S20.20 The Mini Air Ionizer mounts easily in a variety of tested per ANSI/ESD STM3.1 and ESD TR53. positions using the provided tilting bracket/stand. Place the unit on the worksurface and point it at the area or The Mini Air Ionizer reduces a static charge of ±1000 V object to be neutralized. Alternatively, the mounting to ±100 V in less than 4 seconds (the discharge time) at bracket may be attached directly to or above the a distance of 1 foot. workstation, or on another supporting structure. Please note that placement of the Mini Air Ionizer is important The power supply for the Mini Air Ionizer is sold in controlling its effectiveness. Its distance from the separately. The Mini Air Ionizer and its accessories are target object will affect the ionizer’s performance. As available as the following item numbers: distance increases, the discharge time will increase. Item Description Connect the RJ-11 terminal from an SCS power adapter 960 Mini Air Ionizer to the back of the Mini Air Ionizer, and connect the power adapter to an appropriate power outlet. Since the 960X/980X Power Adapter, 120 VAC Input, 24 VAC Mini Air Ionizer does not have a power switch, supplying Output, North America Plug power to the unit automatically turns it on. 770753 Power Adapter, 230 VAC Input, 24 VAC Output, UK Plug Operation 770754 Power Adapter, 230 VAC Input, 24 VAC Supplying power to the Mini Air Ionizer through the Output, Europe Plug power socket in the back of the unit will turn it on. A green monitor light is also illuminated on the front of the unit, which indicates that the ionizer is on, and that power is being applied to the emitter points. SCS - 926 JR Industrial Drive, Sanford, NC 27332 East: (919) 718-0000 | West: (909) 627-9634 • Website: StaticControl.com TB-9008 Page 1 of 2 March 2019 © 2019 DESCO INDUSTRIES INC Employee Owned
Specifications Input Voltage and AC Power Adapter Frequency Power Input: (120 VAC External 120 VAC, 60 Hz Adapter) Power Output: 24 VAC, 500 mA Input Voltage and AC Power Adapter Frequency Power Input: (230 VAC External 230 VAC, 50 Hz Adapter) Power Output: 24 VAC, 500 mA Operating Temperature 59 to 95 °F (15 to 35 °C) Figure 2. Using the Mini Air Ionizer inside a pick and Power Consumption 5 W place machine Dimensions 4.5" x 3.3" x 2.0" (including bracket) (114 mm x 84 mm x 51 mm) Maintenance Weight 0.75 lbs (0.3 kg) Occasional cleaning of the case and of the ionizing Balance (Offset ±20 V electrodes are the only routine maintenance procedures Voltage) at 12" required. Neutralization < 4 seconds CLEANING THE CASE (Discharge) Time at 12" Wipe the case with a soft cloth moistened with water. Maximum Airflow 24 CFM If a stronger cleaning solution is required, mild soap with water may be used. The use of any other cleaning Certifications cULus solutions is not recommended. Country of Origin China CLEANING THE EMITTER POINTS NOTE: Disconnect the power to the ionizer whenever cleaning the emitter points. Limited Warranty, Warranty Exclusions, Limit of Liability and RMA Request Instructions When the emitter pionts become dirty, the internal circuitry of the ionizer will be automatically adjusted to See the SCS Warranty - emit an equal amount of positive and negative ions. StaticControl.com/Limited-Warranty.aspx Particulates on the emitter point may, however, inhibit ionization to a limited degree. The emitter points are located between the fan blades and the rear grill. A jet of clean, compressed air can be used to remove dirt on emitter points. If a more rigorous cleaning method is needed to remove particulate, clean the points with a cotton swab dampened with isopropyl alcohol. Access to the points is available through the rear grill. Be careful not to damage the points during cleaning. SCS - 926 JR Industrial Drive, Sanford, NC 27332 East: (919) 718-0000 | West: (909) 627-9634 • Website: StaticControl.com TB-9008 Page 2 of 2 © 2019 DESCO INDUSTRIES INC Employee Owned
Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: S CS: 960