图片仅供参考

详细数据请看参考数据手册

Datasheet下载
  • 型号: 84874320
  • 制造商: Crouzet
  • 库位|库存: xxxx|xxxx
  • 要求:
数量阶梯 香港交货 国内含税
+xxxx $xxxx ¥xxxx

查看当月历史价格

查看今年历史价格

84874320产品简介:

ICGOO电子元器件商城为您提供84874320由Crouzet设计生产,在icgoo商城现货销售,并且可以通过原厂、代理商等渠道进行代购。 84874320价格参考。Crouzet84874320封装/规格:监视器 - 继电器输出, 。您可以下载84874320参考资料、Datasheet数据手册功能说明书,资料中有84874320 详细功能的应用电路图电压和使用方法及教程。

产品参数 图文手册 常见问题
参数 数值
产品目录

工业控制装置,量表机电产品

描述

RELAY MONITOR SPED 24-240VAC ADJ控制器 HSV 24-240VAC UNDR-OVR SPEED MONT

产品分类

其它

品牌

Crouzet USA

产品手册

点击此处下载产品Datasheet

产品图片

rohs

符合RoHS无铅 / 符合限制有害物质指令(RoHS)规范要求

产品系列

控制器,Crouzet Control 84874320C-Lynx

mouser_ship_limit

该产品可能需要其他文件才能进口到中国。

数据手册

点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet

产品型号

84874320

产品目录页面

点击此处下载产品Datasheet

产品种类

控制器

其它名称

646-1157

其它有关文件

点击此处下载产品Datasheet

商标

Crouzet Control

大小

90 mm x 60 mm x 35 mm

安装

DIN Rail

控制方法

Stored program control

显示器类型

LED Display

标准包装

1

模拟/数字

Analog

特点

Works with either NO or NC sensors

特色产品

http://www.digikey.com/cn/zh/ph/Crouzet/CLynx.html

电源电压

24 V to 240 V

类型

Speed Control

系列

C-Lynx

输入端数量

1

输出端数量

2

输出类型

SPDT

推荐商品

型号:2903522

品牌:Phoenix Contact

产品名称:工业自动化与控制

获取报价

型号:IFMR0036

品牌:Red Lion Controls

产品名称:工业自动化与控制

获取报价

型号:DUR110A

品牌:Crouzet

产品名称:工业自动化与控制

获取报价

型号:2903528

品牌:Phoenix Contact

产品名称:工业自动化与控制

获取报价

型号:DPA02CM40

品牌:Carlo Gavazzi Inc.

产品名称:工业自动化与控制

获取报价

型号:84871033

品牌:Crouzet

产品名称:工业自动化与控制

获取报价

型号:84871030

品牌:Crouzet

产品名称:工业自动化与控制

获取报价

型号:84873024

品牌:Crouzet

产品名称:工业自动化与控制

获取报价

样品试用

万种样品免费试用

去申请
84874320 相关产品

TLA21010

品牌:Red Lion Controls

价格:

DPA51CM44

品牌:Carlo Gavazzi Inc.

价格:¥769.66-¥979.86

460-575

品牌:Littelfuse Inc.

价格:

DPC01DM48

品牌:Carlo Gavazzi Inc.

价格:¥2687.14-¥2963.24

84871033

品牌:Crouzet

价格:¥1398.07-¥1668.12

DIRT220A

品牌:Crouzet

价格:¥579.56-¥613.88

84873221

品牌:Crouzet

价格:¥721.89-¥970.63

2903528

品牌:Phoenix Contact

价格:

PDF Datasheet 数据手册内容提取

02/11/2015 www.crouzet.com DIN Rail Mount 35 mm HSV Part number 84874320 Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact type Works with either NO or NC sensors Time between pulses adjustable from 0.05 s to 10 min. Power-on inhibit time, adjustable from 0.6 to 60 s Inhibit time can be managed via an external contact Part numbers Type Nominal voltage (V) 84874320 HSV 24 →240 V AC/DC Specifications Supply Supply voltage Un 24 V →240 V AC/DC Voltage supply tolerance -15 % / +10 % Operating range 20,4 V →264 V AC/DC Polarity with DC voltage No AC supply voltage frequency 50 / 60 Hz ±10 % Galvanic isolation of power supply/measurement No Power consumption at Un 5 VA in AC/3 W in DC Immunity from micro power cuts 50 ms Inputs and measuring circuit Input circuit 3-wire sensors PNP or NPN, 12V, 50 mA max. Input circuit NAMUR sensor 12 V / 1.5 KΩ * Input circuit Contact 12 V / 9.5 KΩ Input circuit Voltage input 0 V min. /30 V max. /9.5 KΩ High state 4.5 V min. Low state 1 V max. Minimum pulse time 5 ms in high and low state Frequency of measured signal 1.5 m Hz minimum, 22 Hz maximum Measurement ranges 0,5 s - 1 s - 5 s - 10 s - 1 mn - 5 mn - 10 mn Threshold adjustment 10 →100 % of the range Fixed hysteresis 5 % of displayed threshold Display precision ±10 % of full scale Repetition accuracy with constant parameters ± 0,5 % Measuring error with voltage drift < 1 % across the whole range Measuring error with temperature drift ± 0,1 % / °C max. Timing Maximum threshold crossing response time 15 ms Reset time S2 50 ms minimum (in memory mode) Reset time In memory mode (power break) : 1500 ms minimum Inhibit time delay On energisation : 0,6 →60 s (0, +10 % of full scale) Repetition accuracy with constant parameters ± 0,5 % Delay on pick-up 50 ms Display precision ±10 % of full scale Output Type of output 1 single pole changeover relay Type of contacts No cadmium Maximum breaking voltage 250 V AC/ DC Max. breaking current 5A AC/DC Min. breaking current 10 mA / 5 V DC Electrical life (number of operations) 1 x 105 Breaking capacity (resistive) 1250 VA AC Maximum rate 360 operations/hour at full load Operating categories acc. to IEC/EN 60947-5-1 AC 12, AC 13, AC 14, AC 15, DC 12, DC 13, DC 14 Mechanical life (operations) 30 x 106 Insulation Nominal insulation voltage IEC/EN 60664-1 250 V Insulation coordination (IEC/EN 60664-1) Overvoltage category III : degree of pollution 3 Rated impulse withstand voltage (IEC/EN 60664-1) 4 KV (1,2 / 50 μs) Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected

02/11/2015 www.crouzet.com Dielectric strength (IEC/EN 60664-1) 2 kV AC 50 Hz 1 min Insulation resistance (IEC/EN 60664-1) > 500 MΩ / 500 V DC General characteristics Display power supply Green LED Display relay Yellow LED Inhibit display Yellow LED Casing 35 mm Mounting On 35 mm symmetrical DIN rail, IEC/EN 60715 Mounting position All positions Material : enclosure plastic type VO to UL94 standard Incandescent wire test according to IEC 60695-2-11 & NF EN 60695-2-11 Protection (IEC/EN 60529) Terminal block : IP20 Casing : IP30 Weight 120 g Connecting capacity IEC/EN 60947-1 Rigid : 1 x 42 - 2 x 2.52 mm2 1 x 11 AWG - 2 x 14 AWG Flexible with ferrules : 1 x 2.52 - 2 x 1.52 mm2 1 x 14 AWG - 2 x 16 AWG Max. tightening torques IEC/EN 60947-1 0,6 →1 Nm / 5,3 →8,8 Lbf.In Operating temperature IEC/EN 60068-2 -20 →+50 °C Storage temperature IEC/EN 60068-2 -40 →+70 °C Humidity IEC/EN 60068-2-30 2 x 24 hr cycle 95 % RH max. without condensation 55 °C Vibrations according to IEC/EN60068-2-6 10 →150 Hz, A = 0.035 mm Shocks IEC/EN 60068-2-6 5 g Standards Marking CE (DBT) 2006/95/EC - EMC 2004/108/EC Product standard NF EN 60255-6 / IECI 60255-6 / UL 508 / CSA C22.2 N°14 Electromagnetic compatibility (EMC) Immunity EN 61000-6-2/IEC 61000-6-2 Emission EN 61000-6-4/EN 61000-6-3 IEC 61000-6-4/IEC 61000-6-3 Emission EN 55022 class B Certifications UL, CSA Conformity with environmental directives RoHS Comments Accessories Description Code Removable sealable cover for 35 mm casing 84800001 Principles Overview The HSV relay controls the speed (or, more strictly speaking, the operating rate, or frequency) of a process (moving walkway, conveyor, etc.) using discrete sensors : - 3-wire PNP or NPN output proximity sensor - voltage input 0 - 30 V - NAMUR proximity sensor - volt-free contact It can be used to monitor under OR overspeed Operating principle Measurement The monitored process cycle is the succession of pulses characterised by a signal with two states : high and low. The speed measurement is obtained by measuring the duration of this signal, from the first detected change of state (either a rising or falling edge). Digital signal processing avoids the problem of disparity of signals. From energisation, or after the appearance (or reappearance) of the sensor signal, detection (characterisation) of the signal requires processing of one or more periods (two maximum). During this time, control is inoperative. Operating mode Using the selector switch, select one of four modes : - Underspeed without latching - Underspeed with latching - Overspeed without latching - Overspeed with latching If, on energisation, the switch is placed in one of the three intermediate positions (between "underspeed with latching" and "overspeed with latching"), the relay stays in the rest state ("alarm") and the error is signalled by all three LEDs flashing simultaneously. The mode selector switch position is taken into account on energisation. Modifications made during operation will have no effect : the active configuration may therefore be different from that indicated by the switch, the relay operates normally but the change in configuration is signalled by all three LEDs flashing simultaneously. Latching In "memory" mode, when a fault has been recorded, the HSV relay latches in the rest position ("alarm" operational state). Once the speed is correct again, the relay can be unlatched (reset) by closing contact S2 (for 50 ms minimum). Irrespective of the speed of the controlled process, when S2 is closed the HSV relay is inhibited, the output is at the operating point ("normal" operational state) ; if the speed is still not correct when contact S2 is reopened, the relay latches again in the rest position ("alarm" operational state). The HSV can also be reset, by switching off and on again several times in succession (the power break must last at least 1500 ms). If the process speed is incorrect, this method is limited by the same restriction as resetting using S2. Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected

02/11/2015 www.crouzet.com Principles After the end of the inhibit delay on starting, "Ti", as soon as the measured speed drops below the threshold value, the output relay changes state, from operating point to rest position ("alarm" operational state, 11-14 open and 11-12 closed). It returns to the initial state when the speed rises above the threshold plus the hysteresis (fixed at 5 % of the displayed threshold). After the power supply returns, following a break that has lasted at least 1500 ms, the relay is in the ("normal") operating state during the time delay and stays there until the speed is above the threshold. No Legend Voltage (S1) Threshold Inhibit LED Relay Inhibit delay on starting (Ti) 1500 ms min. Speed Principles When the HSV has been configured in "memory" mode, if underspeed is detected, the output relay stays in the rest state ("alarm") irrespective of any subsequent change in the speed of the process. It will not be able to revert to ("normal") operating state until contact S2 closes (50 ms minimum). If, when S2 reopens, the speed is inadequate, the relay reverts to the rest latched state ("alarm"). The HSV can also be reset by a power break (1500 ms minimum) ; the relay then returns to the ("normal") operating state for at least the duration of the time delay, irrespective of the speed of the process. No Legend Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected

02/11/2015 www.crouzet.com Voltage (S1) Contact S2 Threshold Inhibit LED Relay Inhibit delay on starting (Ti) 50 ms min. 1500 ms min. Speed Principles After the end of the inhibit delay on starting, "Ti", as soon as the measured speed rises above the threshold value, the output relay changes state, from operating point to rest position ("alarm" operational state, 11-14 open and 11-12 closed). It returns to the initial state when the speed falls back below the threshold minus the hysteresis (fixed at 5 % of the displayed threshold). After a power break that has lasted at least 1500 ms, the relay is in the ("normal") operating state during the time delay and stays there until the speed is below the threshold. No Legend Voltage (S1) Threshold Inhibit LED Relay Inhibit delay on starting (Ti) 1500 ms min. Speed Principles On energisation, to allow the controlled process to reach its nominal operating speed, the HSV relay is inhibited for a period that is adjustable from 0.6 to 60 seconds. Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected

02/11/2015 www.crouzet.com This time delay can be modified during inhibition to be shorter or longer. The HSV relay can also be inhibited by the closing of contact S2 : on starting, for example, if the process acceleration time is more than 60 s, or at any time during operation. Irrespective of the origin (delay on starting or S2 closing), inhibition maintains the output relay in the''closed'position'' ("normal" operational state, contacts 11-14 closed and 11-12 open) and is signalled by the Inhibit LED lighting up. If, after removal of the inhibition (end of delay on starting or opening of contact S2), the signal detection phase has not ended, the relay drops out after the expected time between two pulses (measured from the end of inhibition). Inhibition must last for as long as required for the product to detect at least 2 periods. If the signal type has not been determined at the end of the inhibit period, the "inhibit" LED flashes for as long as it is impossible to measure the speed. Similarly, during operation, it is possible to inhibit the HSV relay at any time by closing S2. No Legend Voltage (S1) Contact S2 Threshold Inhibit LED Relay Inhibit delay on starting (Ti) Speed Principles When the HSV has been configured in "memory" mode, if overspeed is detected, the output relay stays in the rest state ("alarm") irrespective of any subsequent change in the speed of the process. It will not be able to revert to ("normal") operating state until contact S2 closes (50 ms minimum). If, when S2 reopens, the speed is too high, the relay reverts to the rest latched state ("alarm"). The HSV can also be reset by a power break (1500 ms minimum) ; the relay then returns to the ("normal") operating state for at least the duration of the time delay, irrespective of the speed of the process. No Legend Voltage (S1) Contact S2 Threshold Inhibit LED Relay Inhibit delay on starting (Ti) 50 ms min. 1500 ms min. Speed Principles Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected

02/11/2015 www.crouzet.com It is possible to inhibit the HSV relay by closing external contact S2 until the process has reached its nominal speed. No Legend Voltage (S1) Contact S2 Threshold Inhibit LED Relay Inhibit delay on starting (Ti) Speed Dimensions (mm) HSV mm Connections HSV - Input circuits Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected

02/11/2015 www.crouzet.com No Legend S2 Inhibition - Reset Entrée contact sec 12 V, 9,5 kΩ Connections Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected

02/11/2015 www.crouzet.com No Legend S2 Inhibit - Reset NAMUR proximity sensor input 12 V, 1.5 kΩ Connections Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected

02/11/2015 www.crouzet.com No Legend S2 Inhibit - Reset 3-wire PNP/NPN proximity switch 12 V, 50 mA max. Connections Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected

02/11/2015 www.crouzet.com No Legend S2 Inhibit - Reset Voltage input 0 V - 30 V Connections CA 84874320 CA 84874320 Product adaptations Customisable colours and labels Possible to delete settings Fixed threshold in the generic measurement range Fixed or adjustable time delay Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected