ICGOO在线商城 > 2026-07-C4
数量阶梯 | 香港交货 | 国内含税 |
+xxxx | $xxxx | ¥xxxx |
查看当月历史价格
查看今年历史价格
2026-07-C4产品简介:
ICGOO电子元器件商城为您提供2026-07-C4由Bourns设计生产,在icgoo商城现货销售,并且可以通过原厂、代理商等渠道进行代购。 提供2026-07-C4价格参考以及Bourns2026-07-C4封装/规格参数等产品信息。 你可以下载2026-07-C4参考资料、Datasheet数据手册功能说明书, 资料中有2026-07-C4详细功能的应用电路图电压和使用方法及教程。
参数 | 数值 |
产品目录 | |
描述 | GAS DISCHARGE TUBE 3 POLE |
产品分类 | 气体放电管避雷器 (GDT) |
品牌 | Bourns Inc. |
数据手册 | |
产品图片 | |
产品型号 | 2026-07-C4 |
rohs | 含铅 / 不符合限制有害物质指令(RoHS)规范要求 |
产品系列 | TRIGARD™ 2026 |
产品培训模块 | http://www.digikey.cn/PTM/IndividualPTM.page?site=cn&lang=zhs&ptm=16064 |
其它名称 | 202607C4 |
包装 | 管件 |
安装类型 | 通孔 |
容差 | ±20% |
封装/外壳 | 轴向圆柱形,3引线(径向弯曲) |
故障短接 | 无 |
极数 | 3 |
标准包装 | 100 |
电压-DC火花放电(标称值) | 75V |
电流-AC放电(标称值) | 20A |
脉冲放电电流(8/20us) | 20kA |
Features Applications n Balanced TRIGARD® n Telecommunications n Approximately 8 mm diameter, 11 mm long n Industrial electronics n UL Recognized n Commercial electronics n Custom configurations available n Consumer electronics n High surge current rating n Stable breakdown throughout life n RoHS compliant* version available 2026 Series - 3-Pole Gas Discharge Tube Characteristics Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards. Model No. Characteristic 2026-07 2026-09 2026-15 2026-20 2026-23 2026-25 2026-26 DC Sparkover ±20 % @ 100 V/s (1) 75 V 90 V 150 V 200 V 230 V 250 V 260 V Impulse Sparkover (2) 100 V/µs 275 V 275 V 350 V 425 V 450 V 475 V 475 V 1000 V/µs 700 V 600 V 575 V 625 V 650 V 700 V 700 V Model No. Characteristic 2026-30 2026-35 2026-40 2026-42 2026-47 2026-60 DC Sparkover ±20 % @ 100 V/s (1) 300 V 350 V 400 V 420 V 470 V 600 V Impulse Sparkover (2) 100 V/µs 550 V 625 V 675 V 725 V 800 V 925 V 1000 V/µs 775 V 875 V 925 V 1000 V 1100 V 1250 V (1) In ionized mode. (2) Impulse Sparkover voltage is defined as typical values of distribution. Impulse Transverse Delay .............................................1000 V/µs .................................................................< 75 ns Insulation Resistance ...................................................100 V (50 V for Model 2026–07 & 2026-09) .............> 1010 Ω Glow Voltage ................................................................10 mA .......................................................................~ 70 V Arc Voltage ...................................................................1A .............................................................................~ 10 V Glow-Arc Transition Current ...........................................................................................................................< 0.5 A Capacitance .................................................................1 MHz .......................................................................< 2 pF DC Holdover Voltage (3) ...............................................>135 V, (52 V for Model 2026-07 & 2026-09, ...........< 150 ms 80 V for Model 2026-15) Impulse Discharge Current ...........................................20000 A, 8/20 µs (4) .................................................. 10 operations 5000 A, 10/350 µs ................................................... 1 operation 1000 A, 10/1000 µs ................................................. 400 operations Alternating Discharge Current ......................................130 Arms, 11 cycles (4) ............................................. 1 operation minimum 20 Arms, 1 s ............................................................. 10 operations Operation and Storage Temperature .............................................................................................................. -40 to +90 °C Climatic Category (IEC 60068-1) .................................................................................................................... 40/ 90/ 21 Moisture Sensitivity Level ............................................................................................................................... 1 ESD Classification (HBM) ............................................................................................................................... N/A An optional Switch-Grade Fail-Short device is available. The optional Fail-Short assembly will activate at a temperature of 215 °C – 217 °C to provide a high conductive path to ground in case of a thermal overload. GDTs equipped with the optional Fail-Short device should be soldered either manually at a temperature that is below the activation temperature of the Fail-Short mechanism, or using a selective soldering process that does not exceed 210 °C. Notes: • Model number marking on tube: 26-xxx V. • The rated discharge current for TRIGARD® Gas Discharge Tubes is the total current equally divided between each line to ground. • Sparkover limits after life ±25 %, IR >108Ω (-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60). • Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage. • At delivery AQL 0.65 Level II, DIN ISO 2859 (3) Network applied. (4) DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting. *RoHS Directive 2015/863, Mar 31, 2015 and Annex. Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. WARNING Cancer and Reproductive Harm The products described herein and this document are subject to specific legal disclaimers as set forth www.P65Warnings.ca.gov on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
2026 Series - 3-Pole Gas Discharge Tube Product Dimensions (additional lead form configurations available upon request) 2026-XX-A1 2026-XX-C4 7.9 ± 0.3 7.9 ± 0.3 DIA. (.311 ± .012) 11.3 ± 0.4 (.311 ± .012) DIA. (.445 ± .016) 7.5 ± 0.4 (.295 ± .016) 13.5 ± 0.4 1.0 ± 0.04 (.531 ± .016) (.039 ± .002) DIA. 1.0 ± 0.04 1.0 ± 0.04 0.85 ± 0.2 (.039 ± .002) (.039 ± .002) (.033 ± .008) 5.85 ± 0.6 5.85 ± 0.6 (.230 ± .024) (.230 ± .024) 2026-XX-C2 7.9 ± 0.3 (.311 ± .012) 13.0 ± 0.8 DIA. (.511 ± .031) 2026-XX-C 1.0 ± 0.08 mm (.039 ± .002 in.) dia. lead wire 7.5 ± 0.4 DIA. 30.5 ± 0.4 (.295 ± .016) 7.9 ± 0.2 (.311 ± .008) 11.3 ± 0.4 (1.201 ± .016) 15.4 ± 0.8 (.449 ± .016) LONG (.606 ± .032) 2 PLCS. 1.0 ± 0.04 (.039 ± .002) 1.0 ± 0.04 (.039 ± .002) 4.4 ± 0.3 4.4 ± 0.3 (.173 ± .012) (.173 ± .012) 1.0 ± 0.04 7.5 ± 0.3 (.039 ± .002) (.295 ± .012) 30 LONG 2026-XX-C3 2 PLCS. 7.9 ± 0.3 DIA. (.311 ± .012) FAIL-SHORT CONFIGURATION 2026-XX-C2F SHOWN 7.5 ± 0.4 8.1 ± 0.3 (.295 ± .016) (.319 ± .012) 13.5 ± 0.4 1.0 ± 0.04 (.531 ± .016) 1.0 DIA. 7.5 (.039 ± .002) 1.0 ± 0.04 (.039 ± .002) 4.7 ± 0.3 9.6 ± 0.4 (.185 ± .012) 4.7 ± 0.3 (.378 ± .016) (.185 ± .012) MM DIMENSIONS: (INCHES) UNITS WITH LEADS ARE BASED ON THE 2026-XX-A1 BODY. Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
2026 Series - 3-Pole Gas Discharge Tube How to Order Packaging Specifications 2026 - nn - x n F LF Standard Packaging Quantity Model Number Model Bulk (Bag) Tray Box Designator Voltage (Divided by 10) 2026-XX-A1 250 1000 07 = 75 V 30 = 300 V 09 = 90 V 35 = 350 V 2026-XX-C 50 300 15 = 150 V 40 = 400 V 2026-XX-C2 100 1000 20 = 200 V 42 = 420 V 23 = 230 V 47 = 470 V 2026-XX-C3 100 1000 25 = 250 V 60 = 600 V 26 = 260 V 2026-XX-C4 100 1000 Leads A = None C = 1 mm Lead Shape (See Product Dimension Drawings) Fail-Short Option Blank = Standard Product F = With Fail-Short Mechanism RoHS Compliant Option Blank = Standard Product LF = RoHS Compliant Product Agency Recognition / Industry Standards Agency References UL 497B Recognized Component, Category QVGQ2, File E153537 UL 497 Recognized Component, Category QVGV2, File E53117 Telcordia GR-974-CORE/ 2026 Series devices, as applicable, are tested to GR requirements for primary protectors GR-1361-CORE Additional Information Click these links for more information: PRODUCT TECHNICAL INVENTORY SAMPLES LIBRARY Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
20236 3S1er2ie -s 2- 3m-Pmole S GMasD D Tisrcimhamrgien Tgu bPeo tentiometer Switch-Grade Fail-short Device Shorting Curve 2026-XX-XF 30.0 20.0 10.0 ) S G T L E 5.0 ( ) A ( t n e r r u C 1.0 0.5 0.1 1 10 100 1000 Seconds ELTGS = Each Line to Ground Simultaneously NOTE: When using a GDT fail-short device, it is imperative that all components associated and connected to the GDT with failsafe be tested in their respective completely integrated environment (finished product) to assure desired operation. REV. G 01/21 Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
Legal Disclaimer Notice This legal disclaimer applies to purchasers and users of Bourns® products manufactured by or on behalf of Bourns, Inc. and its affiliates (collectively, “Bourns”). Unless otherwise expressly indicated in writing, Bourns® products and data sheets relating thereto are subject to change without notice. Users should check for and obtain the latest relevant information and verify that such information is current and complete before placing orders for Bourns® products. The characteristics and parameters of a Bourns® product set forth in its data sheet are based on laboratory conditions, and statements regarding the suitability of products for certain types of applications are based on Bourns’ knowledge of typical requirements in generic applications. The characteristics and parameters of a Bourns® product in a user application may vary from the data sheet characteristics and parameters due to (i) the combination of the Bourns® product with other components in the user’s application, or (ii) the environment of the user application itself. The characteristics and parameters of a Bourns® product also can and do vary in different applications and actual performance may vary over time. Users should always verify the actual performance of the Bourns® product in their specific devices and applications, and make their own independent judgments regarding the amount of additional test margin to design into their device or application to compensate for differences between laboratory and real world conditions. Unless Bourns has explicitly designated an individual Bourns® product as meeting the requirements of a particular industry standard (e.g., ISO/TS 16949) or a particular qualification (e.g., UL listed or recognized), Bourns is not responsible for any failure of an individual Bourns® product to meet the requirements of such industry standard or particular qualification. Users of Bourns® products are responsible for ensuring compliance with safety-related requirements and standards applicable to their devices or applications. Bourns® products are not recommended, authorized or intended for use in nuclear, lifesaving, life-critical or life-sustaining ap- plications, nor in any other applications where failure or malfunction may result in personal injury, death, or severe property or environmental damage. Unless expressly and specifically approved in writing by two authorized Bourns representatives on a case-by-case basis, use of any Bourns® products in such unauthorized applications might not be safe and thus is at the user’s sole risk. Life-critical applications include devices identified by the U.S. Food and Drug Administration as Class III devices and generally equivalent classifications outside of the United States. Bourns expressly identifies those Bourns® standard products that are suitable for use in automotive applications on such products’ data sheets in the section entitled “Applications.” Unless expressly and specifically approved in writing by two authorized Bourns representatives on a case-by-case basis, use of any other Bourns® standard products in an automotive application might not be safe and thus is not recommended, authorized or intended and is at the user’s sole risk. If Bourns expressly identifies a sub-category of automotive application in the data sheet for its standard products (such as infotainment or lighting), such identification means that Bourns has reviewed its standard product and has determined that if such Bourns® standard product is considered for potential use in automotive applications, it should only be used in such sub-category of automotive applications. Any reference to Bourns® standard product in the data sheet as compliant with the AEC-Q standard or “automotive grade” does not by itself mean that Bourns has approved such product for use in an automotive application. Bourns® standard products are not tested to comply with United States Federal Aviation Administration standards generally or any other generally equivalent governmental organization standard applicable to products designed or manufactured for use in aircraft or space applications. Bourns expressly identifies Bourns® standard products that are suitable for use in aircraft or space applications on such products’ data sheets in the section entitled “Applications.” Unless expressly and specifically approved in writing by two authorized Bourns representatives on a case-by-case basis, use of any other Bourns® standard product in an aircraft or space application might not be safe and thus is not recommended, authorized or intended and is at the user’s sole risk. The use and level of testing applicable to Bourns® custom products shall be negotiated on a case-by-case basis by Bourns and the user for which such Bourns® custom products are specially designed. Absent a written agreement between Bourns and the user regarding the use and level of such testing, the above provisions applicable to Bourns® standard products shall also apply to such Bourns® custom products. Users shall not sell, transfer, export or re-export any Bourns® products or technology for use in activities which involve the design, development, production, use or stockpiling of nuclear, chemical or biological weapons or missiles, nor shall they use Bourns® products or technology in any facility which engages in activities relating to such devices. The foregoing restrictions apply to all uses and applications that violate national or international prohibitions, including embargos or international regulations. Further, Bourns® products and Bourns technology and technical data may not under any circumstance be exported or re-exported to countries subject to international sanctions or embargoes. Bourns® products may not, without prior authorization from Bourns and/or the U.S. Government, be resold, transferred, or re-exported to any party not eligible to receive U.S. commodities, software, and technical data. To the maximum extent permitted by applicable law, Bourns disclaims (i) any and all liability for special, punitive, consequential, incidental or indirect damages or lost revenues or lost profits, and (ii) any and all implied warranties, including implied warranties of fitness for particular purpose, non-infringement and merchantability. For your convenience, copies of this Legal Disclaimer Notice with German, Spanish, Japanese, Traditional Chinese and Simplified Chinese bilingual versions are available at: Web Page: http://www.bourns.com/legal/disclaimers-terms-and-policies PDF: http://www.bourns.com/docs/Legal/disclaimer.pdf C1753 05/17/18R